Diagnostic Accuracy of an Abbreviated vs. a Full MRI Breast Protocol in Detecting Breast Cancer: An ROC Study
Rattachement africain : mt. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
Background/Objectives: Comparison of diagnostic accuracy of an abbreviated against a full protocol for breast MRI in detecting breast cancer. Diagnostic accuracy and cancer yield were compared using reporting and data system classification (BI-RADS) against a gold standard: biopsy confirmed carcinoma or negative follow-up on imaging. Diagnostic accuracy determined through receiver operator characteristic (ROC), and calculation of performance indicators. Methods: Thirty-five MRI breast examinations undertaken between January 2019 and December 2021: 20-biopsy confirmed carcinoma and 15-normal (negative follow-up on imaging), were retrospectively retrieved. Two radiologists independently reviewed the abbreviated protocol. Data collected compared with data from initial radiological MRI reports based on the full protocol. Lesions with BI-RADS 1 or 2 considered were considered negative while BI-RADS 3,4 or 5 positive. Results: Area under the curve obtained from each ROC curve (ROCAUC) was: 1 for the full protocol, 0.920 and 0.922 for Radiologist A and B respectively for the abbreviated protocol. Each protocol diagnosed the disease state (cancer yes/no) at a statistically significant level (p< 0.05). When using the abbreviated protocol, diagnostic accuracy was maintained. All cancers were detected by both radiologists on both abbreviated and full protocol (100% sensitivity). The specificity of the abbreviated protocol was significantly (p< 0.05) lower for both radiologists (A-73.3% and B -53.5%) compared to the full protocol (100% for both). Conclusions: Area under the curve obtained from each ROC curve (ROCAUC) was: 1 for the full protocol, 0.920 and 0.922 for Radiologist A and B respectively for the abbreviated protocol. Each protocol diagnosed the disease state (cancer yes/no) at a statistically significant level (p< 0.05). When using the abbreviated protocol, diagnostic accuracy was maintained. All cancers were detected by both radiologists on both abbreviated and full protocol (100% sensitivity). The specificity of the abbreviated protocol was significantly (p< 0.05) lower for both radiologists (A-73.3% and B -53.5%) compared to the full protocol (100% for both).
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Diagnostic Accuracy of an Abbreviated vs. a Full MRI Breast Protocol in Detecting Breast Cancer: An ROC Study
- Date Crossref
- 06/05/2025
- Éditeur
- MDPI AG
- Type
- posted-content
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.