Clinical efficacy and safety of automatic remifentanil administration based on Analgesia Nociception Index monitoring during burn surgery under propofol anesthesia: A randomized controlled clinical trial

5Citations signalées, ce qui n’est pas une note de qualité
5Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : fr. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

BACKGROUND: Monitoring the nociception/antinociception balance for analgesic guidance during general anesthesia may improve the quality of anesthesia. The University Hospital of Lille (France) has developed an expert software system for automatic remifentanil administration based on the continuous monitoring of the Analgesia Nociception Index (MDoloris, France). We assessed the clinical efficacy and safety of the ANI-REMI-LOOP "expert-system software" during burn surgery in a monocentric randomized controlled trial. METHODS: The trial was approved by the French Ethics Committee, and all patients gave written informed consent. From 2018 to 2022, 52 adults were randomized into two groups: manual remifentanil infusion (standard practice) or automatic remifentanil infusion (expert-system software) during BIS-guided propofol anesthesia at the burn center of the hospital. In the standard practice group, remifentanil administration was based on Minto's model and guided by the analgesia nociception index. In both groups, propofol was administered based on Schnider's model and guided by the BiSpectral Index (Covidien). The primary endpoint was the cumulative remifentanil dose administered during anesthesia and secondary endpoints were related to the clinical safety of automatic remifentanil administration with the incidence and duration of hypotension, bradycardia, hypertension or tachycardia related to nociception. After anesthesia, the endpoints were pain and analgesic requirements during 2 hours. A p value < 0.05 was considered statistically significant. Data are presented as median [1st to 3rd quartile]. RESULTS: The cumulative remifentanil dose was significantly lower in the automatic group 0.125 µg.kg-1.min-1 [0.106 to 0.149] vs. 0.152 µg.kg-1.min-1 [0.137 to 0.237], p = 0.004), and the cumulative proportion of time with hemodynamic impairment or reactivity was significantly lower in the expert-system automatic group 4.2% [2.5 to 5.7] vs. 19.4% [6.9 to 59.9], p = 0.010). There were no safety issues, and pain and analgesic requirements were similar in both groups after surgery. CONCLUSIONS: Automatic remifentanil administration demonstrated good clinical performances during propofol anesthesia for burn surgery. It is likely that these results can be extrapolated to any surgical setting under general anesthesia, but this needs to be tested with further randomized clinical trials.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Clinical efficacy and safety of automatic remifentanil administration based on Analgesia Nociception Index monitoring during burn surgery under propofol anesthesia: A randomized controlled clinical trial
Date Crossref
05/05/2025
Éditeur
Public Library of Science (PLoS)
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Anesthesia and Sedative AgentsAnesthesia and Pain ManagementNausea and vomiting management

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.