Development of a Benchtop Model for Evaluating the Compatibility of Wound Dressing Materials with Negative Pressure Wound Therapy Systems
Rattachement africain : us. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
Negative pressure wound therapy (NPWT) systems facilitate wound healing by applying sub-atmospheric pressure to the wound bed, which promotes granulation tissue formation and reduces inflammation. Wound dressings can be used with these systems to enhance healing; however, the effects of dressings on NPWT device performance are challenging to assess. The purpose of this study was to develop a benchtop flesh analog model for testing the compatibility of wound dressing materials with NPWT devices. In this study, a chitosan-based advanced wound care device was evaluated for its effects on NPWT performance under maximum and minimum therapy pressures. The goal was to use the model to compare pressure readings and fluid collection for samples with and without the chitosan wound care device. The benchtop model was constructed using a plastic box connected to multiple pressure gauges. A circular defect was created on a piece of pork belly, used as the flesh analog, and inserted into the box. The defect was filled with standard NPWT foam or foam combined with the wound dressing. Simulated body fluid containing bovine serum was added to the box, which was then tested at either maximum (-200 mmHg) or minimum (-25 mmHg) pressures for 72 h. Pressure and fluid collection were recorded every 12 h. The NPWT system successfully maintained pressure over the 72 h test period, both with and without the test dressings. The addition of the wound dressings did not impact fluid collection. The test box proved effective as a benchtop model, as it could be sealed and maintained vacuum conditions over the 72 h testing period. This model successfully demonstrated its utility in evaluating the compatibility of wound dressing materials with NPWT systems.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Development of a Benchtop Model for Evaluating the Compatibility of Wound Dressing Materials with Negative Pressure Wound Therapy Systems
- Date Crossref
- 02/05/2025
- Éditeur
- MyJove Corporation
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Où se fait cette recherche
-
University of Tennessee Health Science Center Joint Graduate Biomedical Engineering Program pays non établi dans la noticeUniversité ou école supérieure
-
University of Memphis pays non établi dans la noticeUniversité ou école supérieure
Joint Graduate Biomedical Engineering Program — University of Tennessee Health Science Center et University of Memphis.
Une affiliation ne permet pas de déduire la nationalité d’un auteur.