Trueness, precision, and internal fit of additively and subtractively manufactured definitive resin‐based crowns
Rattachement africain : us, ch, tr. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
PURPOSE: To assess the fabrication trueness, precision, and internal fit of additively manufactured (AM) and subtractively manufactured (SM) resin-based definitive crowns. MATERIALS AND METHODS: A maxillary right first molar complete-coverage crown was designed and fabricated using 2 additively manufactured [Pro Resins Crown X (AM-S); Straumann USA LLC and Flexcera Smile Ultra+ (AM-F); Desktop Health] and 2 subtractively manufactured [Shofu HC (SM-S); SHOFU Dental Corp and Brilliant Crios (SM-C); Coltene/Whaledent AG] resins (n = 15). The crowns were scanned using an intraoral scanner (IOS) and then seated onto the abutment tooth and rescanned. Fabrication trueness was evaluated by superimposing test data (TD) over the reference crown and computing the root mean square (RMS, µm) error for overall, intaglio, and margin surfaces. Internal fit was evaluated by measuring the average gap distance between the crown and abutment tooth (µm) using a modified triple scan protocol (TSP) for overall, occlusal, and axial surfaces. One-way ANOVA followed by post hoc Tukey's comparison tests was used to analyze the data (α = 0.05). RESULTS: Significant differences were observed among the resin-based crown materials for trueness (RMS), precision deviation, and internal fit (p < 0.001). AM-F had the lowest intaglio RMS value. Margin RMS values for AM-F and AM-S were significantly lower than those for SM-C and SM-S (p < 0.001). SM-C and SM-S showed superior occlusal fit compared to AM-F and AM-S (p < 0.001). CONCLUSIONS: The type of CAD-CAM manufacturing method-additive or subtractive-significantly influenced the trueness and internal fit of resin-based definitive crowns.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Trueness, precision, and internal fit of additively and subtractively manufactured definitive resin‐based crowns
- Date Crossref
- 30/04/2025
- Éditeur
- Wiley
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Où se fait cette recherche
-
University at Buffalo pays non établi dans la noticeUniversité ou école supérieure
-
University of Connecticut pays non établi dans la noticeUniversité ou école supérieure
-
University of Bern Department of Restorative pays non établi dans la noticeUniversité ou école supérieure
-
Ankara University pays non établi dans la noticeUniversité ou école supérieure
-
The Ohio State University pays non établi dans la noticeUniversité ou école supérieure
University at Buffalo, University of Connecticut et Department of Restorative — University of Bern, avec 2 autres affiliations.
Une affiliation ne permet pas de déduire la nationalité d’un auteur.