Aller au contenu principal
Accès ouvert déclaré 2025 article

Global Results From the Optimize PRO Study: Standardized TAVR Technique and Care Pathway

4Citations signalées — pas une note de qualité
37Institutions déclarées
10Pays d’affiliation déclarés

Résumé fourni par la source

Background: The safety and efficacy of utilizing standardized implant protocols and care pathways are limited in large global prospective studies of transcatheter aortic valve replacement (TAVR), and institutional variability remains. This analysis aims to report 30-day outcomes from the global Optimize PRO study evaluating valve performance and procedural outcomes using an "optimized" TAVR care pathway and the cusp overlap technique (COT) in patients receiving Evolut PRO/PRO+ valves. Methods: The Optimize PRO study is a multicenter, postmarket, prospective study conducted in 50 centers in the United States, Canada, Europe, the Middle East, and Australia. Patients with symptomatic severe aortic stenosis and no preexisting pacemakers underwent TAVR with standardized optimized preprocedure, periprocedure, and postprocedure pathways. Results: There were 653 patients with attempted TAVR implants, a mean age of 79.1 ± 6.5 years, and a mean Society of Thoracic Surgeons predictive risk of mortality of 3.2% ± 2.5%. The primary 30-day end point of all-cause mortality or all stroke was 5.1%, all-cause mortality 0.8%, and disabling stroke 1.7%. The new 30-day permanent pacemaker implantation rate was 6.4% with 4-step COT compliance and 11.1% overall. At discharge, there were no instances of moderate or severe aortic regurgitation, and 76.2% of patients had none/trace aortic regurgitation. The median length of stay was 2 days. Conclusions: The Optimize PRO study demonstrated low rates of new permanent pacemaker implantation and no moderate to severe aortic regurgitation after TAVR with Evolut PRO/PRO+ using COT and perioperative protocols in a global cohort of severe aortic stenosis patients. Best practices resulted in consistent implantation depth and low complication rates.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Global Results From the Optimize PRO Study: Standardized TAVR Technique and Care Pathway
Date Crossref
01/05/2025
Éditeur
Elsevier BV
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Cardiac Valve Diseases and TreatmentsAortic Disease and Treatment ApproachesCongenital Heart Disease Studies

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, ROR et la Banque mondiale, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune donnée externe enregistrée en base. Sources et limites.