Evaluation of a New Device for Clearing Secretions From Lower Airways

1Citations signalées — pas une note de qualité
5Institutions déclarées
2Pays d’affiliation déclarés

Résumé fourni par la source

Background: Endotracheal intubation promotes the retention of secretions in the lower airways, potentially leading to infections and obstructions. A novel endotracheal cuff controller, synchronized with the ventilator, is designed to remove secretions from both above and below the endotracheal tube (ETT) cuff by generating a semi-automatic “artificial cough” through brief ETT cuff deflation during the inspiratory phase of a ventilator breath. This study assessed, first, in vitro, the accuracy of a computation for estimating the cough flow and, subsequently, in subjects, the device’s effectiveness in moving secretions from lower airways toward the mouth during invasive ventilation. Methods: In the in vitro study, the mean cough flow estimated by the ratio between the expiratory volume lost and the duration of the cuff deflation was compared with the actual cough flow measured using flow meters. In the clinical study, we enrolled subjects admitted to the ICU. Three artificial cough maneuvers were performed within 3 min during a sigh (inspiratory pressure of 35 cm H 2 O for ∼1.8 s). Aspiration of the oral cavity was conducted before the first maneuver and after the third maneuver. Results: A strong linear association was found between actual and computed cough flow (Pearson’s correlation coefficient 0.991, 95% CI: 0.987–0.994). Twenty-eight subjects were enrolled. After device activation, oral secretions were detected in 78.6% of subjects (responders). Cough flow was similar in both responders and nonresponders, with a mean highest value of 23.3 ± 11.5 L/min. Demographic, physiological, and ventilatory parameters before and after the maneuvers were also similar. No relevant adverse events were recorded, except for one transient episode of hypotension. Conclusions: The cough flow can be accurately estimated from the expiratory volume lost. The device successfully generated effective cough flows in all subjects, clearing secretions from the trachea to the mouth in nearly 80% of cases.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Evaluation of a New Device for Clearing Secretions From Lower Airways
Date Crossref
28/04/2025
Éditeur
SAGE Publications
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Combustion and Detonation ProcessesInhalation and Respiratory Drug Delivery

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref et Europe PMC, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune réponse conservée. Sources et limites.