Bent Intramedullary Metacarpal Implants
Rattachement africain : us. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
BACKGROUND: Metacarpal fractures are common injuries that can lead to debilitating outcomes if not treated appropriately. Intramedullary fixation has gained popularity as a treatment option, allowing for earlier mobilization with few reported complications. METHODS: A retrospective chart review of all patients treated with intramedullary implants for a metacarpal fracture between August 2018 and February 2024 at a single center was performed. Medical records and radiographs were reviewed to identify instances of hardware failure/bent implant. In patients with bent implants, the mechanism of re-injury was recorded. RESULTS: 648 total metacarpal fractures were surgically treated during the study period, with 90 patients receiving intramedullary fixation (56 ExsoMed INnate, 31 Acumed acutrak, 3 Arthrex headless compression screw). Five patients (7 screws) experienced postoperative hardware failure/bending of the implant, all resulting from a punching mechanism. Furthermore, all patients with postoperative hardware failure sustained their initial metacarpal fracture as a result of a punching mechanism. Additionally, 1 patient initially treated at an outside hospital presented with a bent implant following a punching-related reinjury. All affected patients were male, and the time from initial surgery to implant failure ranged from 4 weeks to 7 months. CONCLUSION: This series highlights a notable complication (bent implant) associated with intramedullary fixation of metacarpal fractures and includes our strategy for implant removal. Furthermore, we now consider patients with a history of closed-fist striking as a mechanism of injury as a contraindication to intramedullary metacarpal fixation due to this complication.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Bent Intramedullary Metacarpal Implants
- Date Crossref
- 26/04/2025
- Éditeur
- SAGE Publications
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.