An Integrated Nanosensor/Smartphone Platform for Point-of-Care Biomonitoring of Human Exposure to Pesticides
Rattachement africain : us, ca, ru. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
High Resolution Image Download MS PowerPoint Slide Organophosphorus (OP) compounds are neurotoxins that are among the most widely used pesticides in agriculture in the United States. In this application, a new integrated point-of-care smartphone/resistive nanosensor device is developed for onsite rapid and sensitive detection of exposure to OP pesticides from a drop of finger-stick blood among a sample of farmworkers. The nanosensor leverages the transport properties of a multiwalled carbon nanotube/polyaniline nanofiber (MWCNT/PAnNF) nanocomposite film on a gold interdigitated electrode and acetylcholinesterase/butyrylcholinesterase (AChE/BChE) hydrolysis of their respective substrates generating protons doping PAnNFs, thereby increasing the conductance of the film. As such, a conductance change can be used to quantify cholinesterase activity, enabling assessment of acute/chronic OP poisoning. Additionally, a mobile app was developed for the nanosensor to process, display, track, and share results. Under optimal conditions, the nanosensor demonstrated exceptional sensitivity with the detection limits of 0.11 U/mL for AChE and 0.093 U/mL for BChE, physiologically relevant dynamic ranges of 2.0–18.0 U/mL for AChE and 0.5–5.0 U/mL for BChE in whole blood, and high reproducibility with the relative standard variation of <4%. The nanosensor was further validated with widely used radiometric and Ellman’s methods, utilizing both in vitro pesticide-spiked blood samples and blood samples from 22 farmworkers. The results between this nanosensor and those two methods demonstrated a strong agreement. This platform provides a new avenue for the simple, rapid, and sensitive biomonitoring of OP pesticide exposure.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- An Integrated Nanosensor/Smartphone Platform for Point-of-Care Biomonitoring of Human Exposure to Pesticides
- Date Crossref
- 25/04/2025
- Éditeur
- American Chemical Society (ACS)
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.