Aller au contenu principal
Accès ouvert déclaré 2025 article

Doubly Fed Induction Generator Frequency Regulation Enhancement Using Combined Inertia and Proportional Resonant Controller

3Citations signalées — pas une note de qualité
6Institutions déclarées
3Pays d’affiliation déclarés

Résumé fourni par la source

Power systems are currently undergoing a transition from centralized synchronous generators to decentralized non-synchronous generators that rely on renewable energy sources. This shift poses a challenge to system operators, as the high penetration levels of renewable energy introduce variability and changes in the physics of power systems. Load-frequency control is one of the biggest challenges faced by electrical grids, especially with increased wind energy penetration in recent years. The inertial controller is one of the methods used to support system frequency in variable-speed wind turbines. In this study, a proportional resonant (PR) controller was added to an inertial controller to achieve better frequency regulation by controlling the active power of the doubly fed induction generator (DFIG). First, the impact of the PR controller parameters on the frequency deviation, overshoot, settling time, and system stability was investigated to identify the optimal values that achieved the lowest frequency deviation while maintaining system stability. Second, the performance of the proposed method was compared that of the traditional method under different load perturbations. The results prove that improperly determining the proportional gain of the PR controller negatively affects system stability and frequency deviation. In addition, the results validate the hypothesis that the proposed method would provide fast frequency support for all the studied cases. The analysis and simulation of these scenarios were performed using the MATLAB/SIMULINK program.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Doubly Fed Induction Generator Frequency Regulation Enhancement Using Combined Inertia and Proportional Resonant Controller
Date Crossref
23/04/2025
Éditeur
MDPI AG
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Microgrid Control and OptimizationWind Turbine Control SystemsIslanding Detection in Power Systems

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref et Europe PMC, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune réponse conservée. Sources et limites.