Comparison of 18F-FDG PET image quality and quantitative parameters between DPR and OSEM reconstruction algorithm in patients with lung cancer

5Citations signalées — pas une note de qualité
3Institutions déclarées
1Pays d’affiliation déclarés

Résumé fourni par la source

The present study aimed to investigate the influence of the deep progressive learning reconstruction (DPR) algorithm on the 18 F-FDG PET image quality and quantitative parameters. In this retrospective study, data were collected from 55 healthy individuals and 184 patients with primary malignant pulmonary tumors who underwent 18 F-FDG PET/CT examinations. PET data were reconstructed using the ordered subset expectation maximization (OSEM) and DPR algorithms. The influence of DPR algorithm on quantitative parameters was explored, including the SUV max , SUV mean , standard deviation of SUV (SUV SD ), metabolic tumor volume (MTV), total lesion glycolysis (TLG), and tumor-to-background uptake ratio (TBR). Finally, the differences in image quality parameters, including signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR), between the two reconstruction algorithms were evaluated. DPR algorithm significantly reduced the SUV max and SUV SD of background tissues (all, P < 0.001) compared to OSEM algorithm, while no statistical difference was observed in SUV mean between the two algorithms (all, P > 0.05). DPR algorithm notably increased the SUV max , SUV mean , and TBR of lesions (all, P < 0.001) and reduced MTV ( P = 0.005), with minimal differences in TLG noted between the reconstruction algorithms ( P < 0.001). The percentage differences in SUV max ( P = 0.001), SUV mean ( P = 0.005), and TBR ( P = 0.001) between the two algorithms were significantly higher in solid nodules than in pure ground glass nodules (pGGNs). The ΔCNR between solid nodules ( P = 0.031) and mixed ground glass nodules ( P = 0.020) was greater than that between pGGNs. SNR and CNR obtained using the DPR algorithm were markedly improved compared to those determined using the OSEM algorithm (all, P < 0.001). Under identical acquisition conditions, the DPR algorithm enhanced the accuracy of quantitative parameters in pulmonary lesions and potentially improved lesion detectability. The DPR algorithm increased image SNR and CNR compared to those obtained using the OSEM algorithm, significantly optimizing overall image quality. This advancement facilitated precise clinical diagnosis, underpinning its potential to significantly contribute to the field of medical imaging.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Comparison of 18F-FDG PET image quality and quantitative parameters between DPR and OSEM reconstruction algorithm in patients with lung cancer
Date Crossref
16/04/2025
Éditeur
Springer Science and Business Media LLC
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Medical Imaging Techniques and ApplicationsLung Cancer Diagnosis and TreatmentAdvanced Radiotherapy Techniques

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref et Europe PMC, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune réponse conservée. Sources et limites.