Level Reduction of Induced AC Interferences on a Gas Pipeline by Permutation of «phases» of the HVAC Power Line

0Citations signalées — pas une note de qualité
0Institutions déclarées
0Pays d’affiliation déclarés

Résumé fourni par la source

High Voltages (HV) power lines can generate an induced alternating voltage (AC) on nearby gas pipelines. In the ongoing operation of HV power lines, consideration must be given to the risk to the safety of persons and the risk of corrosion that may affect the integrity of the pipeline. It is necessary to carry out studies of reduction of these interferences. When a risk of AC interference on a pipeline has been identified by the proximity of an HV power line, the installation of earthing systems is often the solution. In the documentation, permutation phase is one of the most effective techniques to reduce the level of AC interferences. In this article, we will discuss the case of an energy corridor in France where three natural gas transmission pipelines are subject to strong AC electrical interferences due to the proximity of HV power lines. Without a reduction system, AC voltage levels close to 200 V were simulated in the steady state condition. The usual solution chosen was to set up several earthing systems (nine) after studying the electrical configuration of the structures in the field and by simulation via the CRINOLINE tool. Despite these arrangements, it was found that the alternative voltage had been reduced, but insufficiently in view of the design standards. Therefore, it was decided to try a solution that had rarely been implemented. This solution consists in studying the impact of the spatial layout of the electrical conductors of the HV lines which then led to a phase swap on the HV powerline. Alternative voltage measurements carried out in the field because of this work confirmed the significant level of mitigation.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Level Reduction of Induced AC Interferences on a Gas Pipeline by Permutation of «phases» of the HVAC Power Line
Date Crossref
06/04/2025
Éditeur
AMPP
Type
proceedings-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Sujets associés

Vacuum and Plasma ArcsIndustrial Engineering and TechnologiesThermal Analysis in Power Transmission

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref et Europe PMC, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune réponse conservée. Sources et limites.