Aller au contenu principal
Accès ouvert déclaré 2025 article

Impact of Mitral Valve Transcatheter Edge-To-Edge Repair on Haemodynamic Parameters in Cardiogenic Shock

3Citations signalées — pas une note de qualité
2Institutions déclarées
1Pays d’affiliation déclarés

Résumé fourni par la source

Abstract Background Transcatheter edge-to-edge repair (TEER) has been shown to be an effective treatment option for patients experiencing cardiogenic shock (CS) with concomitant high-grade mitral valve regurgitation. However, haemodynamic changes following M-TEER have not been thoroughly investigated. Afterload mismatch, leading to the deterioration of haemodynamics subsequent to mitral regurgitation correction, could potentially occur and adversely impact prognosis. Our objective was to analyse the effect of TEER on haemodynamic and echocardiographic parameters in patients with CS. Methods and results We conducted a retrospective study of patients undergoing TEER for mitral valve regurgitation in the setting of CS. Haemodynamic and echocardiographic parameters before and after TEER were systematically analysed. A total of 25 patients underwent TEER in the context of CS. All patients were successfully treated with at least of one grade reduction in mitral regurgitation. The median left atrial mean pressure decreased from 23 mmHg (IQR 17–30) to 16 mmHg (IQR 11–20, P < 0.01), and the V-wave decreased from 36 mmHg (IQR 27–44) to 21 mmHg (IQR 14–25, P < 0.01) following the procedure. The stroke volume index and cardiac index increased from 25 mL/m2 (IQR 18–29) to 34 mL/m2 (IQR 25–44, P < 0.01) and from 1.90 L/min/m2 (IQR 1.41–2.30) to 2.50 L/min/m2 (IQR 1.99–2.86, P < 0.01), respectively. We did not observe any worsening of the ejection fraction after the procedure. Ten patients (40%) died during their hospital stay. Conclusions Our study demonstrates that TEER leads to favourable haemodynamic changes in patients with CS. We observed a significant reduction in left atrial pressure, V-wave, and an elevation in cardiac index. Importantly, we did not observe any deterioration in left ventricular function following the procedure. This supports the concept of haemodynamic stabilization with TEER in patients with CS and high-grade mitral regurgitation.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Impact of Mitral Valve Transcatheter Edge-To-Edge Repair on Haemodynamic Parameters in Cardiogenic Shock
Date Crossref
14/04/2025
Éditeur
Oxford University Press (OUP)
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Mechanical Circulatory Support DevicesCardiac Valve Diseases and TreatmentsCardiac Structural Anomalies and Repair

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref et Europe PMC, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune réponse conservée. Sources et limites.