Aller au contenu principal
Accès ouvert déclaré 2025 article

A novel smart guidewire with an integrated hemodynamic sensor for central catheter placement: Design and simulation

1Citations signalées, ce qui n’est pas une note de qualité
5Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : cn. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

OBJECTIVE: We analyzed the differences in hemodynamic patterns along the central venous catheterization pathway and constructed a sensor-at-tip guidewire for real-time detection of temperature field changes related to hemodynamic patterns. The design was verified using COSMOL simulation and in vitro simulation tests to evaluate its potential application as a tool to facilitate navigation during catheterization. METHODS: Differences in the hemodynamic modes in the central venous catheterization pathway led to changes in the temperature field created with a thermal source. A sensor-at-tip guidewire model was used to detect real-time changes in the temperature field during catheterization. By multiphysical coupling of temperature, heating power, thermistor, and fluid velocity fields, a simulation study based on the intrinsic characteristics of thermistor material winding springs was conducted, wherein the coupling relationship between the blood flow velocity (flow rate) and temperature transfer was obtained and the design was verified by simulation. RESULTS: Based on a multiphysics finite element simulation, the application of a thermal flow sensor composed of a thermistor and power resistor in central vein catheterization was verified. Theoretical calculations suggested that the thermal flow sensor can be composed of a conventional wire-wound spring or a commercially available, inexpensive, small-sized (01005 package) negative thermal coefficient resistor. This study provides a low-cost, portable, and real-time navigation solution for hemodynamic monitoring that is expected to have clinical applications. CONCLUSION: The sensitivity and resolution of this design met the requirements of difference analysis for heating power vs. temperature fields as well as hemodynamic changes vs. temperature fields, indicating potential applications in navigation for central venous catheterization.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
A novel smart guidewire with an integrated hemodynamic sensor for central catheter placement: Design and simulation
Date Crossref
01/06/2025
Éditeur
Elsevier BV
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Central Venous Catheters and HemodialysisSoft Robotics and ApplicationsHemodynamic Monitoring and Therapy

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.