Durability of resin bonding to translucent zirconia materials: An in vitro study

5Citations signalées — pas une note de qualité
3Institutions déclarées
3Pays d’affiliation déclarés

Résumé fourni par la source

STATEMENT OF PROBLEM: How the yttria content (3Y-PSZ, 4Y-PSZ and 5Y-PSZ) affects the tensile bond strength of luting resin to translucent zirconia ceramics is unclear. PURPOSE: The purpose of this in vitro study was to evaluate whether the bond strength of resin to translucent zirconia ceramics and its durability are influenced by the yttria content (3Y-PSZ, 4Y-PSZ and 5Y-PSZ). MATERIAL AND METHODS: Sixty-four disk-shaped specimens of zirconia ceramics were randomly allocated to 4 groups (n=16) with respect to the yttria concentration: GHT: 3 mol% yttria-partially stabilized zirconia 3Y-PSZ; GHTML: 3 mol% yttria-partially stabilized multilayered zirconia 3Y-PSZ; GSTML: 4 mol% yttria-partially stabilized zirconia 4Y-PSZ; and GUTML: 5 mol% yttria-partially stabilized zirconia 5Y-PSZ. For bonding, acrylic resin tubes were filled with composite resin and bonded to the zirconia disks using adhesive luting resin by following manufacturer's instructions. Half of each main group (n=8) was stored in water for 3 days at 37 °C. The other half was stored in water for 150 days with 37 500 thermocycles (5 to 55 °C). The tensile bond strength test was determined with a universal testing machine at a crosshead speed of 2 mm/minute using a chain loop for alignment. RESULTS: The tensile bond strength was not significantly affected by the yttria concentration of different zirconia materials (3Y-PSZ, 4Y-PSZ, and 5Y-PSZ, P=.17). The mean ±standard deviation failure loads for groups ranged from 24.1 ±2.6 MPa for the ultratranslucent multilayered zirconia (with thermocycling) to 52.7 ±5.4 MPa for the high translucent multilayered zirconia (without thermocycling). However, artificial aging adversely affected the tensile bond strength values for all tested zirconia systems (P<.001). Scanning electron microscope evaluation showed that cohesive fracture was the predominant failure mode, while few specimens exhibited adhesive failure at the interface. CONCLUSIONS: The yttria concentration (3Y-PSZ, 4Y-PSZ, and 5Y-PSZ) had no significant effect on the bond strength of different zirconia ceramics (P=.17), whereas the artificial aging procedures led to a statistically significant decrease in tensile bond strength (P<.001).

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Durability of resin bonding to translucent zirconia materials: An in vitro study
Date Crossref
01/06/2025
Éditeur
Elsevier BV
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Dental materials and restorationsDental Implant Techniques and OutcomesAnatomy and Medical Technology

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, ROR et la Banque mondiale, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune donnée externe enregistrée en base. Sources et limites.