Aller au contenu principal
Accès ouvert déclaré 2025 article

Effects of super high-flux vitamin E–coated and medium cut-off dialyzers on uremic toxins removal and biocompatibility: the E-FLUX randomized controlled study

3Citations signalées — pas une note de qualité
3Institutions déclarées
1Pays d’affiliation déclarés

Résumé fourni par la source

ABSTRACT Background Medium cut-off hemodialysis (MCO-HD) improves removal of middle molecules (MM) uremic toxins. The effects of the novel super high-flux vitamin E–coated (SHFVE) dialyzer on MM removal and biocompatibility parameters including inflammation and oxidative stress remain to be investigated. Methods This non-inferiority cross-over prospective randomized study included 36 patients randomly assigned to receive either 3 months of MCO-HD followed by 3 months of SHFVE-HD, or vice versa. The primary endpoint was beta2-microglobulin reduction ratio (RR) after 3 months. Secondary endpoints were other MM RR and biocompatibility parameters. Results SHFVE-HD provided non-inferior beta2-microglobulin RR as compared with MCO-HD {74.2% [95% confidence interval (CI) 71; 77] vs 73.3% (95% CI 71; 76) with a difference of 0.9% (95% CI –1.9%; 3.6), respectively}, with similar mean RR of prolactin, alpha1-microglobulin, vascular endothelial growth factor, and kappa and lambda free light chains. SHFVE-HD induced lower mean myoglobin RR compared with MCO-HD (55.5 ± 7.3 vs 60.2 ± 6.6%, P = 0.022). Myoglobin pre-dialysis levels were not significantly different [160 (118–199) vs 167 (167–240) µg/L, P = .08]. Median pre-dialysis levels of interleukin-6 [0.8 (0–4.4) vs 1.7 (0.2–7.2) pg/mL, P = .032], asymmetric dimethylarginine (ADMA) [163 (122–260) vs 167 (133–270) ng/mL, P = .01), mean pre-dialysis serum soluble tumor necrosis factor receptor 1 (sTNFR1) levels (12.7 ± 3.5 vs 13.6 ± 3.6 ng/mL, P = .039) and mean post-dialysis oxidized low-density lipoprotein levels (54 ± 18 vs 63 ± 22 ng/mL, P = .01) decreased significantly with SHFVE-HD. SHFVE-HD induced a significantly lower median relative variation in blood leucocyte count 15 min after dialysis initiation [–3.5 (–6.8 to 1.6) vs –6.2 (–12.9 to –1.5) %, P = .009], encompassing both polymorphonuclear neutrophils and monocytes. Conclusion Compared with MCO-HD, SHFVE-HD appears to provide similar MM RR and may be associated with improved biocompatibility parameters. Trial registration: ClinicalTrials.gov NCT05610683. Data deposited at Centre de la recherche clinique CHU Poitiers

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Effects of super high-flux vitamin E–coated and medium cut-off dialyzers on uremic toxins removal and biocompatibility: the E-FLUX randomized controlled study
Date Crossref
11/04/2025
Éditeur
Oxford University Press (OUP)
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Dialysis and Renal Disease ManagementAcute Kidney Injury ResearchCentral Venous Catheters and Hemodialysis

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref et Europe PMC, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune réponse conservée. Sources et limites.