Purpose This study aims to develop a highly reproducible and efficient method for inducing lens nucleus hardening in porcine eyes using a microwave surgical device. The resulting cataract model eyes simulate key aspects of cataract surgery, offering an effective platform for enhancing surgical training. Methods Freshly enucleated porcine eyes were prepared. A microwave surgical device with a pencil-type electrode (PE) and needle-type electrode (NE) was utilized. The PE was inserted through a scleral incision 4 mm from the corneal limbus, positioned at the center of the lens nucleus, and activated at 50 mW for 30 seconds to create a nucleus cataract model eye. The NE was inserted through a scleral incision 8 mm from the corneal limbus, directed towards the vitreous cavity, and activated at 10 mW for less than 10 seconds to create a posterior polar cataract model eye. The created nucleus cataract model eyes (n=23) were evaluated using a phacoemulsification machine's cumulative dissipated energy (CDE) value. Results Thermal coagulation effectively induced nuclear sclerosis, creating a cloudy nucleus cataract model eye without compromising corneal opacity. The anterior capsule was stained with trypan blue to simulate poor visibility in white cataracts, facilitating capsulorhexis training. The hardened lens nucleus allowed for the practice of phaco-chop and divide-and-conquer techniques with realistic tactile feedback, similar to actual cataract surgery. The mean CDE value of the 23 nucleus cataract model eyes was 8.25, indicating increased nuclear hardness. Additionally, posterior capsule thermal denaturation via the vitreous cavity successfully created a posterior polar cataract model eye. Hydrodelineation and irrigation/aspiration were performed without causing posterior capsular rupture. Conclusion This study presents a novel method to create realistic nucleus and posterior polar cataract models using a microwave surgical device in porcine eyes. These models provide a reproducible and effective platform for surgical training, simulating key aspects of cataract surgery, including capsulorhexis under poor visibility and phacoemulsification techniques.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Various Cataract Model Eyes for Wet Lab Training Using the Microwave Surgical Device
Date Crossref
09/04/2025
Éditeur
Springer Science and Business Media LLC
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Où se fait cette recherche

  • Kawasaki Medical School pays non établi dans la notice
    Université ou école supérieure
  • Osaka Red Cross Hospital Ophthalmology pays non établi dans la notice
    Établissement de santé
  • Ophthalmology pays non établi dans la notice
    Institution

Kawasaki Medical School, Ophthalmology — Osaka Red Cross Hospital et Ophthalmology.

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Intraocular Surgery and LensesRetinal and Optic ConditionsNasal Surgery and Airway Studies

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.