Aller au contenu principal
Accès ouvert déclaré 2025 article

Design and fabrication of multiplex microfluidic LAMP PCR for simultaneous detection of opportunistic protozoa

3Citations signalées, ce qui n’est pas une note de qualité
2Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : ir. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Intestinal parasites are a health problem in many regions, especially in developing countries. Giardia lamblia , Cryptosporidium spp., and Enterocytozoon bieneusi are of great diagnostic importance, particularly in immunocompromised patients and children. This study aimed to develop a multiplex microfluidic LAMP (MμLAMP) PCR for rapid detection of three protozoa. The LAMP primers were designed for the parasites. The microfluidic disk with different compartments was designed using AutoCAD software and fabricated by laser beam. After DNA extraction, the amplifications were performed for all positive samples using MμLAMP PCR. Sensitivity and specificity of tests were calculated and the results were compared to the real-time PCR. The LAMP analysis revealed that 29/30 (96.7 %), 12/19 (63.2 %), and 25/30 (83.3 %) samples were positive for G. lamblia , Cryptosporidium spp., and E. bieneusi , respectively. The specificity results of the LAMP method were high and the sensitivity test results indicated that the LAMP method has the ability to detect 180 ag/μL of G. lamblia DNA, 2.5 fg/μL of Cryptosporidium spp. DNA, and 34 ag/μL of E. bieneusi DNA. The multiplex accuracy results of microfluidic disk showed that none of two-parasite DNA mixes with their non-specific primers cause false positive results. The present study simultaneously detects G. lamblia , Cryptosporidium spp., and E. bieneusi . The current results indicate that the MμLAMP PCR method is a rapid, sensitive, and highly specific method for simultaneous detection of G. lamblia , Cryptosporidium spp., and E. bieneusi in clinical studies, making it a suitable tool for screening and point of care (PoC) testing. • The MμLAMP was designed to detect G. lamblia , Cryptosporidium spp., and E. bieneusi . • The Microfluidic LAMP simultaneously detected all three protozoa with high specificity and sensitivity. • The LoDs of test were 180 ag/μL, 2.5 fg/μL, and 34 ag/μL for G. lamblia , Cryptosporidium spp., and E. bieneusi , respectively.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Design and fabrication of multiplex microfluidic LAMP PCR for simultaneous detection of opportunistic protozoa
Date Crossref
01/06/2025
Éditeur
Elsevier BV
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Biosensors and Analytical DetectionBacteriophages and microbial interactionsAdvanced biosensing and bioanalysis techniques

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.