EICROC: an ASIC to read-out the AC-LGAD sensors for the Electron-Ion Collider (EIC)
Rattachement africain : fr, pl. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
Abstract The ASIC EICROC is designed to read out the AC-LGAD detectors for the future EIC at Brookhaven National Laboratory (BNL). These detectors should combine excellent temporal (20–30 ps) and spatial (≈20 µm) resolution, enabling a new generation of pixel detectors with precise time measurement. Designing an ASIC to read out the AC-LGAD detectors represents a significant technological challenge. The EICROC ASIC measures and digitizes the charge and the Time-of-Arrival (ToA) with a resolution of 25 ps, transmitting these data to the back-end electronics. The first prototype, EICROC0, was submitted using CMOS 130 nm node in 2022.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- EICROC: an ASIC to read-out the AC-LGAD sensors for the Electron-Ion Collider (EIC)
- Date Crossref
- 01/04/2025
- Éditeur
- IOP Publishing
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.