Respiratory motion control during stereotactic thermal ablation of malignant liver tumors: clinical solutions to a technical problem
Rattachement africain : us. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
Percutaneous thermal ablation is a minimally invasive treatment option for select liver tumors. Stereotactic guidance for percutaneous thermal ablation depends on reliable respiratory motion control to maintain a consistent liver location and shape throughout the procedure for image acquisition and ablation probe placements. This is necessary to achieve accurate ablation probe placement and improve pre- to post-ablation image fusion for ablative margin assessment. In this prospective registry-based study, patients undergoing stereotactic percutaneous thermal ablation at a large academic cancer center in the United States between June 2023 and August 2024 were included. We compare lateral targeting errors between three subsequently introduced respiratory motion control techniques and investigated the influence of body mass index (BMI) on lateral targeting errors. In addition, we compare overall organ motion and deformation between intra-procedure pre- and post-ablation CT imaging using a biomechanical deformable image registration technique. We showed that High frequency jet ventilation resulted in higher targeting accuracy (3.7mm vs. 5.6 mm; p = 0.029) and mitigated the influence of BMI (r = -0.27 vs. r = 0.28) compared to breath holds with and without end tidal CO2 monitoring. Overall organ deformation between pre- and post-ablation CT imaging was not significantly reduced compared to breath holds (0.29 cm vs. 0.32 cm, p = 0.25). High frequency jet ventilation is the preferred option for respiratory motion control during stereotactic percutaneous thermal ablation of liver tumors. However, deformable image registration is still necessary for most cases for accurate assessment of sufficient ablative margins.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Respiratory motion control during stereotactic thermal ablation of malignant liver tumors: clinical solutions to a technical problem
- Date Crossref
- 07/04/2025
- Éditeur
- SPIE
- Type
- proceedings-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Où se fait cette recherche
-
The University of Texas MD Anderson Cancer Center pays non établi dans la noticeÉtablissement de santé
-
The Univ. of Texas M.D. Anderson Cancer Ctr. (United States) pays non établi dans la noticeInstitution
The University of Texas MD Anderson Cancer Center et The Univ. of Texas M.D. Anderson Cancer Ctr. (United States).
Une affiliation ne permet pas de déduire la nationalité d’un auteur.