Aller au contenu principal
Accès ouvert déclaré 2025 article

Craniospinal irradiation for medulloblastoma tumors: Retrospective analysis of dosimetric comparison—An institutional study

0Citations signalées, ce qui n’est pas une note de qualité
2Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : in. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

INTRODUCTION: The comparative study of dosimetric parameters for craniospinal irradiation (CSI) in medulloblastoma cancer patients has been conducted using three different radiation treatment modalities, such as helical intensity-modulated radiation therapy (RT) (HIMRT), helical three-dimensional (3D) conformal RT (H3DCRT), and volumetric modulated arc therapy (VMAT). Evaluation based on dosimetric parameters has been performed to check the better clinical outcomes of recent treatment techniques over one another. MATERIALS AND METHODS: In this retrospective study, twenty patients have been taken who were suffering from average-risk medulloblastoma. For these patients, phase 1 and phase 2 treatment plans were generated with HIMRT, H3DCRT, and VMAT using Accuray Precision version 2.0.1.1 and Monaco version 5.51.10 treatment planning software (TPS). For dose calculation, the convolution superposition algorithm is used for HIMRT and H3DCRT and the Monte Carlo algorithm is used for VMAT. RESULT: Homogeneity index (HI), conformity index (CI), heterogeneity index (HT), total treatment time (TT), and doses to organs at risk (OARs) have been calculated. Statistical analysis has been performed with a paired-samples test in Statistical Package for the Social Sciences (SPSS) software version 22. For target volume PTV_Brain, Conformity index in different treatment techniques are mentioned (HIMRT = 1.02 ± 0.016, H3DCRT = 1.04 ± 0.015, VMAT = 1.11 ± 0.090), homogeneity indexes is (HIMRT = 0.73 ± 0.088, H3DCRT = 0.39 ± 0.208, VMAT = 0.43 ± 0.102), and Heterogeneity index is (HIMRT = 1.51 ± 0.013, H3DCRT = 1.50 ± 0.017, VMAT = 1.09 ± 0.018). For target volume PTV_Spine Conformity index in different treatment techniques are mentioned (HIMRT = 1.00 ± 0.004, H3DCRT = 1.01 ± 0.013, VMAT = 1.07 ± 0.039), homogeneity indexes is (HIMRT=0.07 ± 0.043, H3DCRT =0.06 ± 0.070, VMAT = 0.23 ± 0.183), and Heterogeneity index is (HIMRT = 1.10 ± 0.12, H3DCRT = 1.11 ± 0.121, VMAT = 1.06 ± 0.007). For target volume Boost_GTV Conformity index in different treatment techniques are mentioned (HIMRT = 1.035 ± 0.016, H3DCRT = 1.04 ± 0.016, VMAT = 1.08 ± 0.05), homogeneity indexes is (HIMRT = 0.80 ± 0.090, H3DCRT = 0.44 ± 0.223, VMAT = 0.56 ± 0.105), and Heterogeneity index is (HIMRT = 1.27 ± 0.006, H3DCRT = 1.26 ± 0.009, VMAT = 1.07 ± 0.009). Total Treatment time (minutes) for phase 1 in different techniques (HIMRT = 17.77 ± 3.974, H3DCRT = 14.83 ± 3.750, VMAT = 9.72 ± 0.713) and for phase 2 treatment time (HIMRT = 1.99 ± 0.306, H3DCRT = 1.68 ± 0.326, VMAT = 3.39 ± 0.918). All techniques, such as HIMRT, H3DCRT, and VMAT, give a uniform and conformal target coverage, but HIMRT shows the best conformal and homogeneous dose distribution and better OAR sparing. CONCLUSION: In this study, CSI patients treated with HIMRT showed better results in terms of conformity, homogeneity, and doses to organs at risk.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Craniospinal irradiation for medulloblastoma tumors: Retrospective analysis of dosimetric comparison—An institutional study
Date Crossref
01/01/2025
Éditeur
Ovid Technologies (Wolters Kluwer Health)
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Où se fait cette recherche

  • Lovely Professional University pays non établi dans la notice
    Université ou école supérieure
  • Government Medical College Department of Radiation Oncology pays non établi dans la notice
    Université ou école supérieure
  • School of Physical Sciences and Chemical Engineering Department of Physics pays non établi dans la notice
    Université ou école supérieure
  • Mohan Dai Oswal Cancer Hospital and Research Foundation Department of Radiation Oncology pays non établi dans la notice
    Établissement de santé

Lovely Professional University, Department of Radiation Oncology — Government Medical College et Department of Physics — School of Physical Sciences and Chemical Engineering, avec 1 autre affiliation.

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Advanced Radiotherapy TechniquesGlioma Diagnosis and TreatmentBrain Metastases and Treatment

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.