Impact of a deep progressive reconstruction algorithm on low-dose or fast-scan PET image quality and Deauville score in patients with lymphoma

3Citations signalées, ce qui n’est pas une note de qualité
7Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : cn. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

BACKGROUND: F-FDG by up to 2/3 in a real-world deployment with DPR. The aim of this study is to assess the impact of the use of DPR on Deauville score (DS) and clinical interpretation of PET/CT in patients with lymphoma. METHODS: F-FDG PET imaging for during or post-treatment follow-up from November 2020 to February 2024 were prospectively enrolled. The patients were randomly assigned to two groups, including the 1/3 standard dose group and the standard dose group. Forty-four patients were injected with 1/3 standard dose (1.23 MBq/kg) and scanned for 6 min per bed and were reconstructed: ordered-subsets expectation maximization (OSEM) with 6 min per bed (OSEM_6 min_1/3), OSEM_2 min_1/3 and DPR_2 min_1/3. Forty-three patients were scanned according to the standard protocol (3.7 MBq/kg) and were reconstructed: OSEM with 2 min per bed (OSEM_2 min_full), OSEM_40 s_full and DPR_40 s_full. Additionally, the conventional 5-point scale measurement analysis was performed and DS for lymphoma were determined in different groups. Wilcoxon signed-rank test was used to compare the mean values of liver SUVmax and mediastinal blood pool (MBP) SUVmax in each group. Likert scale and DS were evaluated using Wilcoxon signed rank test. RESULTS: The patients with OSEM_6 min_1/3 and DPR_2 min_1/3 showed good image quality with 5(5,5) and 5(4,5) of Likert scoring, as well as the patients with OSEM_2 min_full and DPR_40 s_full. No significant difference was found between the OSEM_6 min_1/3 and DPR_2 min_1/3 groups in terms of liver SUVmax and MBP SUVmax (P = 0.452 and 0.430), as well as the patients with OSEM_2 min_full and DPR_40 s_full (P = 0.105 and 0.638). No significant difference was found between the OSEM_6 min_1/3 and DPR_2 min_1/3 groups in terms of lesion SUVmax (P = 0.080). There was a significant differences in lesion SUVmax between OSEM-2 min_full with DPR-40 s_full (P = 0.027). The DS results were consistent (100%) between OSEM-6 min_1/3 with DPR_2 min_1/3, and between OSEM-2 min_full with DPR-40 s_full, respectively. CONCLUSIONS: DPR reconstruction demonstrated feasibility in reducing PET injection dose or scanning time, while ensuring the preservation of image quality and DS for during or post-treatment follow-up patients with lymphoma.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Impact of a deep progressive reconstruction algorithm on low-dose or fast-scan PET image quality and Deauville score in patients with lymphoma
Date Crossref
02/04/2025
Éditeur
Springer Science and Business Media LLC
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Medical Imaging Techniques and ApplicationsLymphoma Diagnosis and TreatmentRadiomics and Machine Learning in Medical Imaging

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.