Aller au contenu principal
Accès ouvert déclaré 2025 article

Optimal Frequency for Cranial Electromagnetic Field Stimulation

4Citations signalées, ce qui n’est pas une note de qualité
2Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : us. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Background Communication among neurons generates electromagnetic fields (EMFs) that can be measured through a noninvasive, portable helmet equipped with 20 sensors. The EMF data reveal a variety of EMF patterns that have yet to be elucidated. Understanding a propagated frequency from the brain and its subunits can assist with diagnosing the brain and its subunits' function and treatment. Here, the authors provide an interpretation of the EMF patterns with an emphasis on frequency. Methods From January 2025 to February 2025, a prospective clinical study was conducted to enroll patients greater than 18 years old diagnosed with atraumatic and traumatic brain injury whose EMFs, which were collected using a helmet equipped with 20 sensors, were obtained within 24 hours of presentation. EMF data were collected using DAQami software (DATAQ Instruments Inc., Akron, Ohio, United States) and analyzed using fast Fourier transformation with Igor Pro 8 software (WaveMetrics Inc., Lake Oswego, Oregon, United States). Based on each patient's clinical presentations and/or radiographic findings, the sensors of interest, their opposing sensors, and frequencies of interest (FOIs) were selected. Results A total of 10 patients were enrolled with a mean age of 47.1 years. Mechanisms of injury included spontaneous hypertensive intracranial hemorrhage (one patient) and head trauma after a motor vehicle collision, dirt bike accident, or ground-level fall (nine patients). Radiographic findings included spontaneous basal ganglia hemorrhage (one patient), isolated traumatic subdural hematoma (one patient), traumatic subarachnoid hemorrhage (one patient), and no intracranial abnormalities (seven patients). The following targeted FOIs were found: 5.2 Hz, 7.3 Hz, 7.6 Hz, 7.7 Hz, 7.9 Hz, 8.3 Hz, 8.6 Hz, 8.7 Hz, 9.5 Hz, and 10.4 Hz. Conclusions EMF of the human brain reveals changes in neuronal activities in atraumatic and traumatic brain injury patients. This information allows for the localization of sites of brain injuries and the selection of frequencies that can be used for understanding the EMF frequency and function on the macroscopic level as well as at the cellular level. This specific information can then be utilized for stimulation to modulate the changes in neuronal, circuit, and brain function activities. Our frequency selection technique enables more precise, tailored, and potentially more effective treatment aiming to restore EMF activity.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Optimal Frequency for Cranial Electromagnetic Field Stimulation
Date Crossref
29/03/2025
Éditeur
Springer Science and Business Media LLC
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Où se fait cette recherche

  • Riverside University Health System - Medical Center Neurosurgery pays non établi dans la notice
    Établissement de santé
  • Arrowhead Regional Medical Center Neurosurgery pays non établi dans la notice
    Établissement de santé

Neurosurgery — Riverside University Health System - Medical Center et Neurosurgery — Arrowhead Regional Medical Center.

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

EEG and Brain-Computer InterfacesElectromagnetic Fields and Biological EffectsFunctional Brain Connectivity Studies

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.