Perfusion practices and safety standards in Pakistan: Insights from a preliminary nationwide survey
Résumé fourni par la source
INTRODUCTION: Perfusion safety in cardiothoracic surgery is critical, particularly in Pakistan where variability in practice standards exists. This survey investigates the current perfusion practices among Pakistani perfusionists, focusing on the adherence to safety standards during cardiopulmonary bypass (CPB) procedures. METHODS: The survey was conducted over two weeks to explore key areas of perfusion practice, including the use of bubble detectors, level detectors, arterial filters, and saturation monitoring during CPB procedures. Out of approximately 350 practicing perfusionists in Pakistan, 66 responded, resulting in a response rate of 18.9%. The data was collected through an online platform, ensuring anonymity and voluntary participation. The survey included mainly Yes/No questions. To ensure reliability and validity, the questionnaire was reviewed by experts, pilot tested, and refined based on feedback, ensuring it was effective in gathering meaningful insights. RESULTS: The survey results indicate a variable use of essential safety devices such as bubble and level detectors, arterial filters, and continuous venous saturation and cerebral saturation monitoring. While some perfusionists adhere to recommended safety protocols, gaps in the use of critical monitoring equipment were evident. CONCLUSION: The findings highlight the need for standardized perfusion practices in Pakistan to ensure safety and efficacy during CPB. Addressing the gaps in the use of safety and monitoring equipment could lead to improved patient outcomes. Further research is needed to explore the barriers to uniform safety standards and to develop strategies for enhancing perfusion safety across the country.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Perfusion practices and safety standards in Pakistan: Insights from a preliminary nationwide survey
- Date Crossref
- 01/06/2025
- Éditeur
- EDP Sciences
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.
Institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.