Assessment of chloramine decay and nitrification potential following orthophosphate addition in a full-scale drinking water distribution system
Rattachement africain : ca. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
Orthophosphate is added into drinking water distribution systems (DWDSs) to reduce lead levels, but its effects on monochloramine decay and microbial activity are underexplored. The main purpose of this study was to determine the effect of orthophosphate addition and increasing monochloramine levels on monochloramine decay in a phosphorus-limited full-scale DWDS using batch tests. The study also evaluated nitrification potential at selected sites in this DWDS after seven years of orthophosphate application, comparing them with findings from a previous study conducted before its introduction. This comparison provides new insights related to orthophosphate's effects in a full-scale DWDS. In the batch test, samples were divided into unprocessed and microbiologically inhibited groups to observe chemical and microbial monochloramine decay over three weeks. The results suggest that orthophosphate may increase microbiological monochloramine decay. Below certain monochloramine levels, defined in previous research as a critical threshold residual (CTR) (0.4–0.7 mg Cl 2 /L), an accelerated decay rate of monochloramine occurred. The study noted higher CTR values in post-orthophosphate samples, suggesting the need for higher minimum monochloramine levels in the DWDS to prevent accelerated decay when using orthophosphate. Nitrite formation during the batch test was more pronounced in post-orthophosphate samples, suggesting that orthophosphate may enhance nitrification potential. • Assessed nitrification and chloramine decay post-orthophosphate addition by a batch test. • Approaches used: chloramine decay coefficients and curves, threshold residual, nitrite formation. • Orthophosphate and high water age increased microbial chloramine decay and nitrification potential. • Higher initial chloramine levels improved chloramine stability.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Assessment of chloramine decay and nitrification potential following orthophosphate addition in a full-scale drinking water distribution system
- Date Crossref
- 01/04/2025
- Éditeur
- Elsevier BV
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Où se fait cette recherche
-
University of Waterloo Department of Civil and Environmental Engineering pays non établi dans la noticeUniversité ou école supérieure
-
Toronto Water pays non établi dans la noticeInstitution
Department of Civil and Environmental Engineering — University of Waterloo et Toronto Water.
Une affiliation ne permet pas de déduire la nationalité d’un auteur.