Evaluation of Surgical Margins with Intraoperative ex vivo PSMA-PET/CT
Rattachement africain : de, us. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
Ziel/Aim: Detection of positive resection margins in surgical procedures of locally advanced tumours is key for minimizing the risk of recurrence. This study aimed at evaluating the accuracy of intraprostatic functional tumour-volume segmentation in intraoperative ex vivo PSMA-PET/CT. Methodik/Methods: Seven high-risk prostate cancer patients received [ 18 F]F-PSMA-1007 prior to radical prostatectomy. After removal of the prostate gland, ex vivo imaging on the AURA 10 PET/CT system (XEOS, Ghent, Belgium) was performed and functional tumour volume was segmented using four semi-automatic segmentation methods. Resection margins and volumes were compared with histopathology. Additionally, a supportive phantom study was conducted to assess segmentation accuracy at low activity concentrations. Ergebnisse/Results: 18 intraprostatic lesions were identified intraoperatively with ex vivo PET/CT. Sensitivity, specificity, positive and negative predictive value with regards to margin detection were up to 83%, 100%, 100%, and 92%, respectively (using an iterative thresholding method). Phantom deduced minimal segmentable activity concentration was approximately 2 kBq/mL. Based on our observations on lesion uptake, we recommend the administration of at least 2 MBq/kg and 0.4 MBq/kg [ 18 F]F-PSMA-1007 for preoperative and intraoperative injections, respectively, to maintain reliable tumour-segmentation. Schlussfolgerungen/Conclusions: Intraoperative ex vivo PSMA-PET/CT tumour segmentation is clinically feasible in high-uptake lesions. Further studies are needed to investigate the value of ex vivo PET/CT-based radioguided surgery in locally advanced tumours. Publication History Article published online: 12 March 2025 © 2025. Thieme. All rights reserved. Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Evaluation of Surgical Margins with Intraoperative ex vivo PSMA-PET/CT
- Date Crossref
- 01/03/2025
- Éditeur
- Georg Thieme Verlag KG
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.