Multiple Multi-Axis Differential Optical Absorption Spectroscopy (MAX-DOAS) instruments have been operating in the Laboratory of Atmospheric Physics (LAP), Thessaloniki, Greece over a decade to monitor trace gases in the troposphere. In this work, we present methodology, applied for the first time in LAP for retrieving total NO 2 columns in the atmosphere by applying the Direct Sun DOAS technique (DS-DOAS) on solar direct radiance spectra acquired with a research grade MAX-DOAS system, Delta. For the retrieval of total NO 2 two spectral fitting methods were tested using cross sections of NO 2 at two different temperatures for the tropospheric and the stratospheric component. The method that is based on concurrent spectral DOAS fittings with NO 2 cross sections at two temperatures (294 K and 220 K) (2T method) produces results of better quality as compared to the method using NO 2 cross section at one 254.5 K (1T method), with latter underestimating the total NO 2 vertical column density by up to 15%. This was verified by the good agreement (correlation coefficient R=0.973) against the total NO 2 columns measured by an independently calibrated collocated Pandora system. Finally, the total NO 2 columns derived from the Delta instrument were compared with collocated observations by S5P/TROPOMI, showing an underestimation of the latter by up to 40% for days with high NO 2 concentrations, while the agreement is better under low NO 2 conditions. The overall agreement between the satellite and Delta system observations is characterized by a correlation coefficient of 0.82 and a mean bias of –2.63 ± 2.75 Pmolec/cm 2 . • A retrieval method was established to obtain the total NO 2 column from direct-sun spectral radiances of a research-grade DOAS system in Thessaloniki, Greece, using NO 2 cross sections at two temperatures (294 K and 220 K). • The retrieval methodology was evaluated by comparison to a collocated Pandora system with a mean difference of -3%. • Based on two years of observations, the TROPOMI instrument onboard the S-5P satellite underestimates the total NO2 column by 21%. • The total NO 2 column at Thessaloniki shows a distinct annual course (higher levels in winter) and ranges from 3 to 35 Pmolec/cm 2 .
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Direct sun total NO2 column measurements at Thessaloniki, Greece with two DOAS systems and comparisons with S5P/TROPOMI
- Date Crossref
- 01/07/2025
- Éditeur
- Elsevier BV
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.