Simulation training significantly improves the performance of novice students achieving the standard transesophageal echocardiography views
Rattachement africain : pl, us. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
BACKGROUND: Transesophageal echocardiography (TEE) is an important cardiovascular imaging modality, offering detailed images surpassing other techniques, including transthoracic echocardiography. TEE's efficacy relies on skilled physicians operating the probe. Adequate TEE training is often overlooked, leading to potential patient discomfort or harm during TEE examinations. TEE simulators address this gap, providing a safe environment for practitioners to enhance their skills. AIMS: Our study aims to assess the progress of TEE novices, namely medical students following a specific learning protocol with a TEE simulator, hypothesizing significant improvements in the time and movements required for simulated TEE views after training. METHODS: The study protocol encompassed the selection of predetermined simulated TEE projections (n = 16), in accordance with the American Society of Echocardiography guidelines, to facilitate a comprehensive examination involving essential TEE manipulations. Students were provided with unrestricted access to video lectures and subsequently underwent the initial assessment (Test 1). Following this, they had a period of one to four weeks for training on the simulator, with unlimited access to TEE simulation. Test 2 was then administered, and calculations were conducted based on the discrepancies between both tests. Analytical parameters comprised the precision of the TEE view, examination time, and the randomity of probe movement (RAR index). Subsequently, two independent experts rigorously compared the two tests and graded each student's performance change as improvement, no change or worsening. RESULTS: Twenty-six Jagiellonian University Medical College students (median age: 22.5, IQR: 22-24) in the 2nd to 6th year and 50% females, with no prior experience of echocardiography or TEE simulator use participated in the study. Students familiarized themselves with online lectures before executing an identical TEE examination protocol. Median duration between Test 1 and Test 2 was 18 days (IQR: 12-28). First, after TEE simulated training, students exhibited a higher frequency of successfully completing the TEE examination without major errors (grade: passed) (P = 0.039). Additionally, precision significantly increased at Test 2 (P < 0.001). The total duration of the simulated TEE examination was significantly shorter in Test 2 than in the initial test (P < 0.001). Furthermore, the RAR index for ante/retroflexion was substantially lower in Test 2, while probe rotation remained similar between tests. Overall, student progress was evident in the majority of cases, with only 2 students showing no improvement after 1-4 weeks of voluntary self-training with the TEE simulator, and 2 more demonstrating a neutral outcome. CONCLUSIONS: The use of a TEE simulator is valuable for learning how to perform proper and safe simulated TEE examinations. It is effective even for students without prior echocardiographic experience, improving precision, shortening examination time, and reducing unnecessary movements during simulated TEE. TEE simulation is an ideal learning tool for both students and cardiovascular clinicians to minimize mistakes in their practice.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Simulation training significantly improves the performance of novice students achieving the standard transesophageal echocardiography views
- Date Crossref
- 07/03/2025
- Éditeur
- Springer Science and Business Media LLC
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Où se fait cette recherche
-
Jagiellonian University Department of Coronary Artery Disease and Heart Failure pays non établi dans la noticeUniversité ou école supérieure
-
John Paul II Hospital pays non établi dans la noticeÉtablissement de santé
-
Institute of Cardiology pays non établi dans la noticeStructure de recherche
-
AM Technologies (Poland) pays non établi dans la noticeEntreprise
-
AGH University of Krakow Department of Automatic Control and Robotics pays non établi dans la noticeUniversité ou école supérieure
-
Simulation Technologies (United States) pays non établi dans la noticeEntreprise
-
Medical Simulation Technologies pays non établi dans la noticeInstitution
-
Noninvasive Cardiovascular Laboratory pays non établi dans la noticeStructure de recherche
Department of Coronary Artery Disease and Heart Failure — Jagiellonian University, John Paul II Hospital et Institute of Cardiology, avec 5 autres affiliations.
Une affiliation ne permet pas de déduire la nationalité d’un auteur.