Aller au contenu principal
Accès ouvert déclaré 2025 article

Safety and efficacy of lesion size index guided 50 W radiofrequency ablation in patients with paroxysmal atrial fibrillation

1Citations signalées, ce qui n’est pas une note de qualité
4Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : cn. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Pulmonary vein isolation (PVI) using conventional power (30–35 W) radiofrequency ablation (RFA) has been an effective treatment strategy for paroxysmal atrial fibrillation (PAF), but its longer duration may cause collateral damage to peripheral tissue including esophageal and phrenic nerve. High-power (HP) RFA, due to better transmural performance and shorter duration, may reduce the damage to adjacent tissue and is expected to be a safe and efficient ablation strategy. In this retrospective cohort study, we included 259 patients with PAF who underwent lesion size index (LSI)-guided radiofrequency ablation. All patients underwent PVI-based ablation, and some underwent additional ablation, including superior vena cava isolation, tricuspid isthmus block, or left anterior atrial matrix modification. A total of 119 PAF patients underwent 50 W ablation. Complications and twelve-month arrhythmia-free outcomes of the procedure were compared with those of 140 patients who underwent 30–35 W ablation. PVI was successfully achieved in all patients. The procedural duration (140.3 ± 34.4 vs. 151.3 ± 40.6 min, P = 0.022) and overall radiation (112.0 ± 67.2 vs. 188.2 ± 119.2 mGy·cm2, P < 0.001) were significantly lower in the 50 W group. No major complications occurred in the high-power short-duration (HPSD) group, whereas in the conventional power group, five participants developed complications. Among them, three cases were related to venipuncture, one had pericardial tamponade, and one had slight pericardial effusion. The recurrence of arrhythmia at the twelve-month follow-up was not significantly different between the two groups [11 (9.2%) vs. 19 (13.6%), P = 0.278]. LSI-guided HPSD-RFA was demonstrated to be comparably safe and efficacious compared to conventional ablation and resulted in reduced procedure time and radiation exposure. Central Illustration. Safety and Efficacy of Lesion Size Index Guided 50 W Radiofrequency ablation in Patients with Paroxysmal Atrial Fibrillation. A total of 259 patients with paroxysmal atrial fibrillation underwent lesion size index (LSI)-guided radiofrequency ablation were enrolled. High-Power Short-Duration ablation reduced total procedure time, significantly decreased radiation exposure, and had similar recurrence rate of atrial fibrillation.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Safety and efficacy of lesion size index guided 50 W radiofrequency ablation in patients with paroxysmal atrial fibrillation
Date Crossref
07/03/2025
Éditeur
Springer Science and Business Media LLC
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Atrial Fibrillation Management and OutcomesCardiac Arrhythmias and TreatmentsCardiac tumors and thrombi

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.