Mirror dual cleaning of ITER equatorial diagnostic Wide Angle Viewing System
Rattachement africain : ch, fr, es. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
• Wide Angle Viewing System First Mirror Unit manufactured. • Powering M1 and M2 in a dual cleaning configuration allowed for the removal of contaminants with RF plasma. • Mineral insulating cables successfully tested for a maximum temperature of 230 °C for 200 W. • A stratified mirror prototype demonstrates an efficient RF power transmission. The metallic first mirrors (FMs) are expected to play a crucial role in most optical diagnostic systems in the International Thermonuclear Experimental Reactor (ITER). However, these mirrors will be subjected to deposition of the first-wall materials, which will comprise their optical properties. Thus, the FMs will require periodic cleaning to restore their optical properties, which is anticipated to be achieved using an in situ plasma cleaning technique employing radio-frequency (RF) discharges. The left tangential line of sight of the Wide Angle Viewing System (WAVS) for the ITER Equatorial Port 12 FM unit, designed by CEA Cadarache, was simplified and manufactured at the University of Basel for RF-cleaning tests in a realistic geometry. Plasma ignition on mirrors M1 and M2 was achieved at a frequency of 13.56 MHz. Both mirrors were successfully cleaned with a 20-nm aluminum oxide (Al 2 O 3 ) film replicating a contaminant layer. However, powering M1 and M2 in a dual cleaning regime with argon atmosphere at 1 Pa with 100 W of RF power for 1h and 45min (with a −300 V self-bias) allowed for the simultaneous removal of the Al 2 O 3 layer from the rhodium mirror insets on both mirrors. The temperature of the mineral insulating (MI) cables used for powering the first mirror remained well below the maximum rated temperature. A cleaning demonstration was also performed on a stratified mirror prototype developed by CEA. The effectiveness of the dual cleaning technique for the Equatorial Port 12 WAVS diagnostic was validated by powering both FMs in a direct-current (DC) coupled regime, as all reported diagnostics will use a DC decoupled mode.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Mirror dual cleaning of ITER equatorial diagnostic Wide Angle Viewing System
- Date Crossref
- 01/05/2025
- Éditeur
- Elsevier BV
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.