Aller au contenu principal
Accès ouvert déclaré 2025 review

Comparative efficacy and safety of drug-coated balloons versus drug-eluting stents in small vessel coronary artery disease: an updated systematic review and meta-analysis of randomized controlled trials

5Citations signalées, ce qui n’est pas une note de qualité
12Institutions déclarées
5Pays d’affiliation déclarés

Rattachement africain : in, pk, gd, ph, Égypte. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

BACKGROUND: Small vessel coronary artery disease presents challenges in percutaneous coronary intervention due to higher restenosis rates with traditional treatments. Drug-coated balloons (DCBs) offer a potential alternative, but their efficacy compared to drug-eluting stents (DES) remains debated. This meta-analysis aims to provide updated insights into the comparative outcomes of DCBs versus DES in small coronary artery disease. MAIN TEXT: Following PRISMA guidelines, a systematic review identified seven randomized controlled trials (RCTs) comparing DCBs with DES for small vessel CAD. Data were extracted and pooled for analysis, assessing outcomes including target lesion revascularization (TLR), target vessel revascularization (TVR), mortality, myocardial infarction (MI), stent/vessel thrombosis, and major adverse cardiovascular events (MACE). Statistical analysis was performed using RevMan version 5.4, employing random-effects models and forest plots with odds ratios (OR) and 95% confidence intervals (CI). Among 1,808 patients across seven RCTs, no significant difference was found in TVR between DCB and DES over 3 years (OR = 0.95, 95% CI [0.58, 1.54], p = 0.82). While initial analyses favoured higher TLR incidence in DES, the trend shifted towards DCB over time, with a non-significant association favouring DCB at 3 years (OR = 0.51, 95% CI [0.26, 1.00], p = 0.05). DCB use was associated with significantly higher rates of MACE and MI at the 3-year mark (MACE: OR = 0.55, 95% CI [0.38, 0.79], p = 0.001; MI: OR = 0.35, 95% CI [0.17, 0.7], p = 0.003), while mortality rates converged between the two interventions over time. Vessel thrombosis rates were similar between DCB and DES. CONCLUSIONS: While DCBs may offer comparable efficacy to DES in terms of TVR and TLR over shorter durations, there is a concerning trend towards higher rates of MACE and MI associated with DCB use at the 3-year mark. Further research with larger sample sizes, longer follow-up durations, and consistent inclusion criteria is needed to elucidate the optimal treatment strategy for small vessel CAD. Until then, DES may be considered a safer option for managing small vessel CAD.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Comparative efficacy and safety of drug-coated balloons versus drug-eluting stents in small vessel coronary artery disease: an updated systematic review and meta-analysis of randomized controlled trials
Date Crossref
26/02/2025
Éditeur
Springer Science and Business Media LLC
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Coronary Interventions and DiagnosticsAcute Myocardial Infarction ResearchCardiovascular Health and Disease Prevention

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.