Llama 3.1 405B Is Comparable to GPT-4 for Extraction of Data from Thrombectomy Reports—A Step Towards Secure Data Extraction
Rattachement africain : de. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
PURPOSE: GPT‑4 has been shown to correctly extract procedural details from free-text reports on mechanical thrombectomy. However, GPT may not be suitable for analyzing reports containing personal data. The purpose of this study was to evaluate the ability of the large language models (LLM) Llama3.1 405B, Llama3 70B, Llama3 8B, and Mixtral 8X7B, that can be operated offline, to extract procedural details from free-text reports on mechanical thrombectomies. METHODS: Free-text reports on mechanical thrombectomy from two institutions were included. A detailed prompt was used in German and English languages. The ability of the LLMs to extract procedural data was compared to GPT‑4 using McNemar's test. The manual data entries made by an interventional neuroradiologist served as the reference standard. RESULTS: 100 reports from institution 1 (mean age 74.7 ± 13.2 years; 53 females) and 30 reports from institution 2 (mean age 72.7 ± 13.5 years; 18 males) were included. Llama 3.1 405B extracted 2619 of 2800 data points correctly (93.5% [95%CI: 92.6%, 94.4%], p = 0.39 vs. GPT-4). Llama3 70B with the English prompt extracted 2537 data points correctly (90.6% [95%CI: 89.5%, 91.7%], p < 0.001 vs. GPT-4), and 2471 (88.2% [95%CI: 87.0%, 89.4%], p < 0.001 vs. GPT-4) with the German prompt. Llama 3 8B extracted 2314 data points correctly (86.1% [95%CI: 84.8%, 87.4%], p < 0.001 vs. GPT-4), and Mixtral 8X7B extracted 2411 (86.1% [95%CI: 84.8%, 87.4%], p < 0.001 vs. GPT-4) correctly. CONCLUSION: Llama 3.1 405B was equal to GPT‑4 for data extraction from free-text reports on mechanical thrombectomies and may represent a data secure alternative, when operated locally.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Llama 3.1 405B Is Comparable to GPT-4 for Extraction of Data from Thrombectomy Reports—A Step Towards Secure Data Extraction
- Date Crossref
- 25/02/2025
- Éditeur
- Springer Science and Business Media LLC
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.