A Novel Approach to Repositioning Peritoneal Dialysis Catheters

0Citations signalées, ce qui n’est pas une note de qualité
2Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : cn. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Introduction: Peritoneal dialysis (PD) is a crucial kidney replacement therapy for patients with end-stage kidney disease. Despite its advantages over hemodialysis (HD), long-term success can be hindered by catheter dysfunction, which often necessitates revision. Currently, surgical treatment methods for PD catheter malfunction include fluoroscopy-guided procedures and laparoscopic or open surgery to salvage or replace the catheter. Here, we introduce the first novel, minimally invasive surgery for repositioning PD catheters. Methods: From November 2021 to May 2024, 8 patients with PD catheter dysfunction underwent this innovative procedure at the Department of Nephrology, Sichuan Provincial People's Hospital. Surgical Procedure: On the side of the original abdominal incision, blunt separation was used to find the PD catheter tunnel segment. The anterior rectus abdominal muscle sheath was incised, followed by separation of the deep polyester sleeve. The original catheter was exposed in the abdominal port or purse-string suture, and the intra-abdominal segment of the dialysis catheter was pulled out. Blunt cleaning around the periphery was performed to ensure that the PD catheter was smooth, and a rigid guidewire was placed through the intra-abdominal segment of the proximal end of the catheter of the first lateral hole. The intra-abdominal segment of the PD catheter was placed into the pelvis via the original catheter in the abdominal port. Clinical data were retrospectively collected, and patients were followed up for safety and efficacy assessment. Results: In a study involving 8 patients, no significant complications were observed, with an immediate imaging success rate of 100% and a clinical PD catheter reset success rate of 75%. The catheter remained patent until the end of the study, with a mean follow-up time of 17.25 ± 9.25 months. Conclusion: This new method for resetting dysfunctional PD catheters demonstrates technical feasibility, simplicity, cost-effectiveness, and safety. It has the potential to emerge as an alternative, particularly suitable for resource-limited settings.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
A Novel Approach to Repositioning Peritoneal Dialysis Catheters
Date Crossref
25/02/2025
Éditeur
S. Karger AG
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Dialysis and Renal Disease ManagementCentral Venous Catheters and HemodialysisCancer Research and Treatment

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.