Mechanical power is not associated with mortality in COVID-19 mechanically ventilated patients

9Citations signalées — pas une note de qualité
64Institutions déclarées
2Pays d’affiliation déclarés

Résumé fourni par la source

BACKGROUND: The relative contribution of the different components of mechanical power to mortality is a subject of debate and has not been studied in COVID-19. The aim of this study is to evaluate both the total and the relative impact of each of the components of mechanical power on mortality in a well-characterized cohort of patients with COVID-19-induced acute respiratory failure undergoing invasive mechanical ventilation. This is a secondary analysis of the CIBERESUCICOVID project, a multicenter observational cohort study including fifty Spanish intensive care units that included COVID-19 mechanically ventilated patients between February 2020 and December 2021. We examined the association between mechanical power and its components (elastic static, elastic dynamic, total elastic and resistive power) with 90-day mortality after adjusting for confounders in seven hundred ninety-nine patients with COVID-19-induced respiratory failure undergoing invasive mechanical ventilation. RESULTS: O. Mechanical power at the initiation of mechanical ventilation was 24.3 (18.9; 29.6) J/min, showing no significant changes after three days. In multivariable regression analyses, mechanical power and its components were not associated with 90-day mortality at the start of mechanical ventilation. After three days, total elastic and elastic static power were associated with higher 90-day mortality, but this relationship was also found for positive end-expiratory pressure. CONCLUSIONS: Neither mechanical power nor its components were independently associated with mortality in COVID-19-induced acute respiratory failure at the start of MV. Nevertheless, after three days, static elastic power and total elastic power were associated with lower odds of survival. Positive end-expiratory pressure and plateau pressure, however, captured this risk in a similar manner.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Mechanical power is not associated with mortality in COVID-19 mechanically ventilated patients
Date Crossref
01/01/2025
Éditeur
Elsevier BV
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Instituto de Salud Carlos IIICentro de Investigación Biomédica en Red de Enfermedades RespiratoriasHospital Clínic de BarcelonaConsorci Institut D'Investigacions Biomediques August Pi I SunyerUniversitat de BarcelonaOspedale San BortoloUniversity of MilanCorporació Sanitària Parc TaulíHospital Universitari Sagrat CorInstitute of Research and Innovation Parc TauliVall d'Hebron Institut de RecercaHospital Universitario de GetafeUniversidad Carlos III de MadridHospital Universitari Arnau de VilanovaInstituto de Investigación Biomédica de LleidaHospital Universitario Virgen del RocíoHospital Universitario La PazHospital Universitario San AgustínHospital Universitari de Santa MariaHospital Universitario HM MadridHM HospitalesCamilo José Cela UniversityUniversidad de AlcaláHospital Universitario Ramón y CajalHospital de CrucesHospital Clínico Universitario de ValladolidHospital Universitario Virgen MacarenaUniversity Hospital Complex Of VigoHospital Clínico Universitario de ValenciaHospital Universitario 12 De OctubreHospital Universitario de MóstolesComplejo Hospitalario Universitario de SantiagoBellvitge University HospitalInstitut d'Investigació Biomédica de BellvitgeHospital de MataróUniversitat Autònoma de BarcelonaUniversidad de CádizHospital General Universitario Gregorio MarañónHospital Nuestra Señora de AlarcosHospital Universitario de ValmeHospital Del MarUniversidad Francisco de VitoriaHospital Universitario Infanta LeonorHospital Universitario Lucus AugustiComplejo Asistencial Universitario de PalenciaUniversidad de OviedoInstituto de Investigación Sanitaria del Principado de AsturiasHospital General De SegoviaHospital Universitario Son EspasesMarqués de Valdecilla University HospitalHospital Universitario Príncipe de AsturiasCentro de Investigación Biomédica en RedHospital Universitari Germans Trias i PujolInstitut de Recerca Biomèdica Catalunya SudHospital Universitari Joan XXIII de TarragonaComplejo Hospitalario de SalamancaHospital Universitari Sant Joan D'AlacantHospital Universitari i Politècnic La FeHospital Son LlatzerUniversidad Fernando Pessoa CanariasHospital Universitario Río HortegaHospital Universitario de LeónComplexo Hospitalario Universitario A CoruñaComplejo Hospitalario de Ourense

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Respiratory Support and MechanismsSepsis Diagnosis and TreatmentIntensive Care Unit Cognitive Disorders

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref et Europe PMC, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune réponse conservée. Sources et limites.