Augmented reality guided versus computed tomography guided percutaneous lung nodule localization: a noninferiority randomized clinical trial

9Citations signalées, ce qui n’est pas une note de qualité
11Institutions déclarées
4Pays d’affiliation déclarés

Rattachement africain : cn, my, it, us. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

HYPOTHESIS: This study hypothesized that augmented reality (AR) technology has comparable accuracy and safety to conventional CT localization in guiding percutaneous transthoracic lung puncture (PTLP) to localize small pulmonary nodules. METHODS: This study was a prospective, non-inferiority randomized clinical trial. Patients were randomly assigned between 23 May 2023, and 26 September 2023. Patients with small peripheral lung nodules (≤2 cm) were recruited. Patients were randomly assigned to either the CT-guided PTLP group or the AR-guided PTLP group, with a 1:1 allocation ratio. The primary outcome was the accuracy of lung nodule localization measured by localization error. The secondary outcomes included procedure duration, radiation exposure dosage and complications. RESULTS: A total of 70 patients underwent either CT- or AR-guided lung nodule localization and subsequent surgeries. Localization error was smaller in the AR-guided group than in the CT-guided group (mean ± SD, 3.1 ± 4.0 mm vs. 5.4 ± 4.2 mm, P = 0.026). The mean difference of localization errors was -2.3 mm (95% CI: - 4.2 to -0.3 mm, P < 0.001 for non-inferiority). Compared to the CT-guided group, the AR-guided group demonstrated significantly lower radiation exposure (mean ± SD, 421 ± 168 vs. 694 ± 229 mGy × cm, P < 0.001) and shorter localization procedure duration (mean ± SD, 8.8 ± 2.3 vs. 14.1 ± 1.8 minutes, P < 0.001), with no statistical difference in complications. CONCLUSIONS: The accuracy of the AR-guided approach is comparable to that of the CT-guided approach in localizing small lung nodules. Furthermore, the utilization of AR technology has been demonstrated to reduce procedural time and minimize radiation exposure for patients.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Augmented reality guided versus computed tomography guided percutaneous lung nodule localization: a noninferiority randomized clinical trial
Date Crossref
24/02/2025
Éditeur
Ovid Technologies (Wolters Kluwer Health)
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Lung Cancer Diagnosis and TreatmentAdvanced Radiotherapy TechniquesHepatocellular Carcinoma Treatment and Prognosis

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.