Aller au contenu principal
Accès ouvert déclaré 2025 article

Evaluating the accuracy of monitoring seizure cycles with seizure diaries

12Citations signalées, ce qui n’est pas une note de qualité
3Institutions déclarées
2Pays d’affiliation déclarés

Rattachement africain : au, se. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

OBJECTIVE: Epileptic seizures occurring in cyclical patterns is increasingly recognized as a significant opportunity to advance epilepsy management. Current methods for detecting seizure cycles rely on intrusive techniques or specialized biomarkers, thereby limiting their accessibility. This study evaluates a non-invasive seizure cycle detection method using seizure diaries and compares its accuracy with cycles identified from intracranial electroencephalography (iEEG) seizures and interictal epileptiform discharges (IEDs). METHODS: Using data from a previously published first in-human iEEG device trial (n = 10), we analyzed seizure cycles identified through diary reports, iEEG seizures, and IEDs. Cycle similarities across diary reports, iEEG seizures, and IEDs were evaluated at periods of 1 to 45 days using spectral coherence, accuracy, precision, recall, and the false-positive rate. RESULTS: A spectral coherence analysis of the raw signals showed moderately similar periodic components between diary seizures/day and iEEG seizures/day (median = .43, IQR = .68). In contrast, there was low coherence between diary seizures/day and IEDs/day (median = .11, IQR = .18) and iEEG seizures/day and IEDs/day (median = .12, IQR = .19). Accuracy, precision, recall scores, and false-positive rates of iEEG seizure cycles from diary seizure cycles were significantly higher than chance across all participants (accuracy (mean ± standard deviation): .95 ± .02; precision: .56 ± .19; recall: .56 ± .19; false-positive rate: .02 ± .01). However, accuracy, precision, and recall scores of IED cycles from both diary and iEEG cycles did not perform above chance, on average. Recall scores were compared across good diary reporters, under-reporters, and over-reporters, with recall scores generally performing better in good reporters and under-reporters compared to over-reporters. SIGNIFICANCE: These findings suggest that iEEG seizure cycles can be identified with diary reports, even in individuals who under- and over-report seizures. This approach offers an accessible alternative for monitoring seizure cycles compared to more invasive methods.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Evaluating the accuracy of monitoring seizure cycles with seizure diaries
Date Crossref
24/02/2025
Éditeur
Wiley
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Epilepsy research and treatmentEEG and Brain-Computer InterfacesFunctional Brain Connectivity Studies

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.