Performance of Digital Mammography-Based Artificial Intelligence Computer-Aided Diagnosis on Synthetic Mammography From Digital Breast Tomosynthesis
Rattachement africain : kr. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
OBJECTIVE: To test the performance of an artificial intelligence-based computer-aided diagnosis (AI-CAD) designed for full-field digital mammography (FFDM) when applied to synthetic mammography (SM). MATERIALS AND METHODS: We analyzed 501 women (mean age, 57 ± 11 years) who underwent preoperative mammography and breast cancer surgery. This cohort consisted of 1002 breasts, comprising 517 with cancer and 485 without. All patients underwent digital breast tomosynthesis (DBT) and FFDM during the preoperative workup. The SM is routinely reconstructed using DBT. Commercial AI-CAD (Lunit Insight MMG, version 1.1.7.2) was retrospectively applied to SM and FFDM to calculate the abnormality scores for each breast. The median abnormality scores were compared for the 517 breasts with cancer using the Wilcoxon signed-rank test. Calibration curves of abnormality scores were evaluated. The discrimination performance was analyzed using the area under the receiver operating characteristic curve (AUC), sensitivity, and specificity using a 10% preset threshold. Sensitivity and specificity were further analyzed according to the mammographic and pathological characteristics. The results of SM and FFDM were compared. RESULTS: = 0.127) than FFDM. SM showed lower sensitivity than FFDM in asymptomatic breasts, dense breasts, ductal carcinoma in situ, T1, N0, and hormone receptor-positive/human epidermal growth factor receptor 2-negative cancers but showed higher specificity in non-cancerous dense breasts. CONCLUSION: AI-CAD showed lower abnormality scores and reduced calibration performance for SM than for FFDM. Furthermore, the 10% preset threshold resulted in different discrimination performances for the SM. Given these limitations, off-label application of the current AI-CAD to SM should be avoided.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Performance of Digital Mammography-Based Artificial Intelligence Computer-Aided Diagnosis on Synthetic Mammography From Digital Breast Tomosynthesis
- Date Crossref
- 01/01/2025
- Éditeur
- XMLink
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Où se fait cette recherche
-
Korea University Department of Radiology pays non établi dans la noticeUniversité ou école supérieure
-
Korea University Guro Hospital pays non établi dans la noticeÉtablissement de santé
-
Korea University Anam Hospital pays non établi dans la noticeÉtablissement de santé
Department of Radiology — Korea University, Korea University Guro Hospital et Korea University Anam Hospital.
Une affiliation ne permet pas de déduire la nationalité d’un auteur.