SiC detector response to tokamak neutron spectra mock-up validated on experimental results
Rattachement africain : it. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
The Silicon Carbide (SiC) Solid State Detector (SSD) is an interesting alternative to diamond detector for fast neutron detection and spectroscopy. Despite this, and unlike diamonds, SiC was never installed on a Tokamak and, thus, was never characterized on a fusion plasma emission. This work aims to predict the response of a SiC when exposed to the neutron spectrum of future Tokamak devices. This is achieved by combining the neutron spectra measured by diamonds during the DTE2 JET campaign with the experimental characterization of SiC at various neutron energies on spallation and DT sources performed in the past through the means of a Geant4 simulation. The SiC response to an ideal thermal plasma and to a neutron and gamma mixed fields are also produced.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- SiC detector response to tokamak neutron spectra mock-up validated on experimental results
- Date Crossref
- 01/05/2025
- Éditeur
- Elsevier BV
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.