Performance analysis of solar-air source heat pump heating system coupled with sand-based thermal storage floor in rural inner Mongolia, China
Rattachement africain : cn. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
The solar-air source heat pump (SASHP) heating system has gained significant attention in rural clean heating renovations. Nonetheless, the lack of low-cost thermal storage terminals in rural areas results in low energy utilization and high electricity consumption. This study proposes a SASHP system coupled with sand-based thermal storage floor and experimentally evaluates its thermal performance in a rural residence in Inner Mongolia, China. The system performance during the entire heating season was discussed under different operating periods of air source heat pump using TRNSYS models. Results demonstrated the SASHP heating system coupled with sand-based thermal storage floor maintained an average indoor temperature of 18.8 °C, even when the outdoor temperatures ranged from −18.4 °C to 12.3 °C. The average coefficient of performance (COP) and solar fraction of the system are 2.6 and 50.9 %, respectively. Operating the air source heat pump in the daytime (Mode 4) reduced the energy consumption and carbon dioxide emission by 28 % compared to the nighttime operation (Mode 3), with improved the COP and solar fraction. However, operating costs vary significantly with local electricity pricing policies. Without peak-valley pricing, the operating costs in Mode 4 are 28 % lower than that in Mode 3, while the operating costs in Mode 4 are only 2.6 % higher than in Mode 3 with peak-valley pricing. These findings provide a valuable reference for the design and operation optimization of SASHP system, which aims to promote the popularization and application of this system in the field of severe cold rural heating. • SASHP system coupled with sand-based thermal storage floor is proposed. • Field-tested and thoroughly assessed system performance in severe cold rural area. • TRNSYS simulation model was developed and validated utilizing measured data. • The optimal operation mode of the system in different tariff areas is proposed.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Performance analysis of solar-air source heat pump heating system coupled with sand-based thermal storage floor in rural inner Mongolia, China
- Date Crossref
- 01/04/2025
- Éditeur
- Elsevier BV
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Où se fait cette recherche
-
Zhongyuan University of Technology pays non établi dans la noticeUniversité ou école supérieure
-
Dalian University of Technology pays non établi dans la noticeUniversité ou école supérieure
-
School of Smarts Energy and Environment pays non établi dans la noticeUniversité ou école supérieure
-
School of Civil Engineering Laboratory of Building Environment and Equipment Engineering pays non établi dans la noticeUniversité ou école supérieure
Zhongyuan University of Technology, Dalian University of Technology et School of Smarts Energy and Environment, avec 1 autre affiliation.
Une affiliation ne permet pas de déduire la nationalité d’un auteur.