Changes in Seated Pulmonary Artery Pressure in Response to Titration of Heart Failure Medications During Ambulatory Monitoring

7Citations signalées — pas une note de qualité
9Institutions déclarées
2Pays d’affiliation déclarés

Résumé fourni par la source

INTRODUCTION: Ambulatory hemodynamic monitoring (AHM) of heart failure (HF) using pulmonary artery pressure (PAP) is marked by frequent changes in HF medications. We are beginning to learn how medication titrations during AHM affect mean PAP (mPAP) measured in the seated position, which reflects most waking hours. METHOD: We analyzed the 12-month data from the PROACTIVE-HF trial of the Cordella Cordella, Endotronix Inc, Naperville, Illinois, United States) PAP sensor system. Seated mPAP was examined in the 14-days before and after isolated changes in medications; only those medications with ≥10 titrations were analyzed. Dependent sample Wilcoxon-signed rank test was used to compare changes in mPAP with titrations. RESULTS: We analyzed 456 subjects (age: 64 years, females: 40%, Black: 18%, HF with reduced ejection fraction: 46%). Loop diuretics (LD) were up-titrated 176 times in 133 patients and down-titrated 113 times in 96 patients. Before LD up-titration, mPAP increased by 1.6 ± 1.0 mm Hg; afterwards, it decreased by 2.3 ± 1.0 mm Hg (P < 0.001), with most reduction occurring within 1 week. Down-titration of LD was followed by an increase of 1.8 ± 1.3 mm Hg (P = 0.004) over the next several days. Similar trends were observed across categories of ejection fraction (≤40% and >40%). Angiotensin receptor neprilysin inhibitor (ARNI) up-titration decreased mPAP by 1.8 ± 1.9 mm Hg (P = 0.042), whereas down-titration increased mPAP by 1.5 ± 1.4 (P = 0.094). Mineralocorticoid receptor antagonist (MRA) up-titration tended to decrease mPAP (1.6 ± 2.5 mm Hg, P = 0.286,) whereas down-titration was followed by a significant increase in mPAP of 3.2 ± 1.6 mm Hg (P = 0.001). CONCLUSION: The AHM platform using seated mPAP data provided valuable insights into its short-term responses to isolated changes in HF medications. The seated mPAP changed expectedly in response to the titration of LD, whereas the degree of response varied for ARNI and MRA. Ongoing investigation will further characterize the timing and variability of responses to inform algorithms for ambulatory management of PAP.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Changes in Seated Pulmonary Artery Pressure in Response to Titration of Heart Failure Medications During Ambulatory Monitoring
Date Crossref
01/01/2026
Éditeur
Elsevier BV
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Non-Invasive Vital Sign MonitoringPulmonary Hypertension Research and TreatmentsHemodynamic Monitoring and Therapy

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, ROR et la Banque mondiale, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune donnée externe enregistrée en base. Sources et limites.