Aller au contenu principal
Accès ouvert déclaré 2025 review

Comparison of Single‐Coil Versus Dual‐Coil Implantable Cardioverter Defibrillator Devices: A Systematic Review and Meta‐Analysis of Efficacy and Extraction‐Related Outcomes

2Citations signalées, ce qui n’est pas une note de qualité
13Institutions déclarées
4Pays d’affiliation déclarés

Rattachement africain : pk, in, us, qa. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

BACKGROUND: Implantable cardioverter defibrillators (ICD) are battery-operated devices used to manage irregular heart rhythms and deliver therapeutic shocks to the heart. This updated systematic review and meta-analysis compares the efficacy and extraction-related outcomes of single-coil versus dual-coil ICDs in view of conflicting data. METHODS: Several databases, including PubMed, Cochrane Library, and Google Scholar, were comprehensively explored dating from inception to April 1, 2024. Data were compared using odds ratio (OR), hazard ratio (HR), and mean differences (MD). A value of p < 0.05 indicated statistical significance. RESULTS: Ultimately, 28 studies were included in this quantitative synthesis. Defibrillation threshold (DFT) indicated statistical superiority in the dual-coil cohort (MD: 0.58; 95% confidence interval [CI]: 0.07-1.09; p = 0.03). In addition, all-cause mortality was significantly elevated in the dual-coil cohort (HR: 0.91; 95% CI: 0.87-0.97; p = 0.001). Furthermore, implant time was significantly lower in the single-coil group (MD: -7.44; 95% CI: -13.44 to -1.43; p = 0.02). Other outcomes, including first shock efficacy, cardiac mortality, post-extraction major complications, post-extraction procedural success, and post-extraction mortality, did not demonstrate any significant statistical differences. CONCLUSION: In conclusion, despite the desirable safety profile of single-coil ICDs, the use of dual-coil ICDs continues to hold merit due to their superior efficacy and advanced sensing capabilities, especially in complex cases. In addition, the perceived risk of a greater adverse profile in dual-coil lead extraction can be refuted by preliminary aggregate results generated within this meta-analysis. However, further robust studies are warranted before arriving at a valid conclusion.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Comparison of Single‐Coil Versus Dual‐Coil Implantable Cardioverter Defibrillator Devices: A Systematic Review and Meta‐Analysis of Efficacy and Extraction‐Related Outcomes
Date Crossref
01/02/2025
Éditeur
Wiley
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Cardiac pacing and defibrillation studiesCardiac electrophysiology and arrhythmiasNeurological disorders and treatments

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.