Real-world smartphone-based point-of-care diagnostics in primary health care to monitor HbA1c levels in people with diabetes
Résumé fourni par la source
Abstract Background The lack of accurate and affordable monitoring of glycated hemoglobin (HbA1c) is a common issue among patients with diabetes in low- and middle-income countries. We aimed to test a tablet- and smartphone-based point-of-care (TSB POC) device against a local laboratory-based measure of HbA1c for monitoring diabetes under real-world conditions. Methods For this cross-sectional clinical method applicability study, capillary and venous blood was collected in duplicate and analyzed at local primary health care centers. For a heterogeneity test, the tests were performed by an expert, and by a team of local nurses. The study was conducted in a multicenter design in rural and urban Aceh, Indonesia in 2019, and included a total of 533 adults. We mainly used Bland-Altman plots to assess the number of readings within the 95%-limits of agreement (LoA) and Deming regressions. Results The results show a mean difference between capillary HbA1c on the test device and the reference method of −0.54 [CI0.95 = −1.6933; 0.6048] with 5.21% of measurements outside the LoA and a Pearson’s r = 0.91 in the Deming Regression. There is no significant difference in test concordance between local nurses and the expert (4.23% versus 5.13% results outside the LoA [CI0.95 = −0.0331; 0.0511]). Conclusions TSB POC for analysis of HbA1c is an acceptable alternative for accessible monitoring of diabetes patients under these conditions. This method could provide access to high-quality diagnostic decisions through regular and cost-effective HbA1c monitoring directly in healthcare facilities, thus providing better access to essential health services.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Real-world smartphone-based point-of-care diagnostics in primary health care to monitor HbA1c levels in people with diabetes
- Date Crossref
- 05/02/2025
- Éditeur
- Springer Science and Business Media LLC
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.
Institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.