Delineation of the brachial plexus by contrast-enhanced photon-counting detector CT and virtual monoenergetic images
Rattachement africain : jp. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
OBJECTIVES: To improve the image quality of the brachial plexus in photon-counting detector CT (PCD-CT) using contrast media and virtual monoenergetic images (VMI). MATERIALS & METHODS: We retrospectively analyzed contrast-enhanced neck PCD-CT images scanned in March-July 2023. Unenhanced and contrast-enhanced images were compared, and then 40-, 70-, and 100-keV VMIs were compared. The qualitative evaluation used a five-point Likert scale regarding overall image quality (IQ), sharpness, and noise. The quantitative evaluation used the standard deviation (SD), signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR). Freidman's test and one-way ANOVA were performed. RESULTS: Forty patients (65 years ± 17, 21 males) were included. The median scores [interquartile range, IQR] for the unenhanced and contrast-enhanced groups were IQ, 3 [2,3] and 4 [3,4] (P < 0.001); sharpness, 3 [2,3] and 4 [3,4] (P < 0.001); and noise, 3 [3,4] and 3 [3,4] (P = 0.63). Mean ± SD scores were SD, 6.7 ± 1.4 and 6.7 ± 1.0 (P = 0.95); SNR, 5.1 ± 1.2 and 5.4 ± 1.4 (P = 0.04); and CNR, 4.8 ± 1.5 and 8.1 ± 2.3 (P < 0.001). The 40-, 70-, and 100-keV groups' IQ were 2 [2,3], 4 [3,4], and 3 [3,4]; their sharpness scores were 2 [2,3], 3 [3,4], and 3 [2,3] (all, P < 0.05). Those for noise were 2 [1-3], 3 [3,4], and 4 [3,4] (all, P < 0.001 except for 70-keV vs.100-keV: P = 0.16). The SDs were 13.1 ± 2.5, 7.5 ± 1.2, and 6.0 ± 1.1. The SNRs were 4.2 ± 1.9, 5.0 ± 1.2, and 5.7 ± 1.5 (all, P < 0.001). The CNRs were 8.7 ± 4.0, 6.8 ± 2.3, and 6.5 ± 2.3 (all, P < 0.001 except for 70-keV vs.100-keV: P = 0.51). CONCLUSION: Contrast-enhanced PCD-CT and VMIs provided good delineation of the brachial plexus.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Delineation of the brachial plexus by contrast-enhanced photon-counting detector CT and virtual monoenergetic images
- Date Crossref
- 01/03/2025
- Éditeur
- Elsevier BV
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.