Aller au contenu principal
Accès ouvert déclaré 2025 article

Inter‐Laboratory Validation of Nodal/Paranodal Antibody Testing

15Citations signalées, ce qui n’est pas une note de qualité
7Institutions déclarées
4Pays d’affiliation déclarés

Rattachement africain : es, nl, de, gb. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

BACKGROUND AND AIMS: Reliable detection of antibodies against nodal targets is vital for the diagnosis of autoimmune nodopathies. The performance characteristics of recently developed in-house assays are unknown. We compared testing at four centres. METHODS: Each submitted 29-40 serum samples to a coordinating centre from one of three groups: (1) autoimmune nodopathy patients, with positive nodal/paranodal antibodies; (2) seronegative patients with other inflammatory neuropathies, and (3) healthy individuals or those with other neurological diseases. The coordinating centre recoded all samples and returned 160 identical aliquots to each testing centre for blinded testing. Once data from all centres had been received by the coordinating centre, unblinded results were returned for analysis. Sensitivity was defined by the proportion of group 1 samples returned as positive. Accuracy was defined as 0.075(sensitivity) + 0.925(specificity). RESULTS: Centres performed various combinations of ELISA, cell-based (CBAs) and teased-nerve fibre assays. All labs produced highly accurate results (96%-100%) and concordance for the overall result across at least 3 or all 4 test centres was observed for 98% and 89% of the samples respectively. However, 10/30 individual assays (6/14 CBAs and 4/16 ELISAs) were less than 90% sensitive. Only 3 assays had more than 1 false positive result (2 ELISAs and 1 CBA). Combining different assay modalities to produce an overall result did not improve accuracy. Inter-laboratory consistency in the determination of antibody subclasses was poor. INTERPRETATION: Although most samples were correctly categorised in all 4 centres, the use of a specific test modality or multiple tests did not guarantee accuracy. Early and repeated interlaboratory testing with sharing of samples is important to understand test performance and reproducibility, identify areas for improvement and maintain consistency. To aid this, we provide detailed methods for the best performing tests. Further standardisation of antibody subclass determination is required.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Inter‐Laboratory Validation of Nodal/Paranodal Antibody Testing
Date Crossref
29/01/2025
Éditeur
Wiley
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Peripheral Neuropathies and DisordersAutoimmune Neurological Disorders and TreatmentsMultiple Sclerosis Research Studies

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.