Aller au contenu principal
Accès ouvert déclaré 2025 review

Robotic-assisted versus conventional total knee arthroplasty: a systematic review and meta-analysis of alignment accuracy and clinical outcomes

31Citations signalées, ce qui n’est pas une note de qualité
8Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : gb. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Background: Robotic-assisted total knee arthroplasty (RA-TKA) has emerged as an alternative to conventional TKA (C-TKA), aiming to improve surgical precision and patient outcomes. This systematic review and meta-analysis study compares the efficacy of RA-TKA versus C-TKA. Methods: A comprehensive search of five databases (PubMed, EMBASE, Web of Science, SCOPUS, and Cochrane Library) was conducted. We included all published randomized controlled trials (RCTs) from inception to August 2024. Meta-analysis was done using RevMan 5.4 package. Results: Twenty-one RCTs involving 2692 patients were involved. RA-TKA demonstrated significantly lower mechanical alignment outlier rates (risk ratio = 0.33, 95% confidence interval (CI)[0.19, 0.59], P = 0.0002) and less deviation from neutral mechanical axis (mean difference, MD = −0.93° [−1.20, −0.66], P < 0.00001) compared to C-TKA. No significant differences were found in WOMAC or Oxford Knee Scores at various follow-up points. RA-TKA was associated with longer operative times (MD = 19.94 minutes [9.2, 30.68], P = 0.0003) but showed no significant difference in intraoperative blood loss. Postoperative Knee Society Scores were slightly higher in the RA-TKA group (MD = 1.03 [0.50, 1.57], P = 0.0002). Conclusion: RA-TKA offers improved mechanical alignment accuracy compared to C-TKA but does not demonstrate superior short to medium-term functional outcomes. The technology is associated with longer operative times. These findings suggest that while RA-TKA may enhance surgical precision, its clinical benefits and cost-effectiveness require further evaluation, particularly in long-term studies.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Robotic-assisted versus conventional total knee arthroplasty: a systematic review and meta-analysis of alignment accuracy and clinical outcomes
Date Crossref
21/01/2025
Éditeur
Ovid Technologies (Wolters Kluwer Health)
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Total Knee Arthroplasty OutcomesOrthopaedic implants and arthroplastyOrthopedic Infections and Treatments

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.