Complex high-risk indicated PCI (CHIP-PCI): is it safe to let fellows-in-training perform it as primary operators?
Rattachement africain : gb. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
BACKGROUND: Training in complex high-risk indicated percutaneous coronary intervention (CHIP-PCI) has frequently been reserved for established operators (consultants/attending) with trainees (fellows-in-training or FIT) being often discouraged from carrying out such procedures as a primary operator due to their high-risk nature. Whether the outcomes of these cases differ if the primary operator is a supervised FIT compared with a consultant is unknown. METHODS: Using multicentre PCI data from three cardiac centres in South Wales, UK (2018-2022), we identified 2295 CHIP-PCI cases with a UK-BCIS CHIP Score of 3 or more. These were then divided by primary operator status (supervised FIT vs consultant); the primary outcome was in-hospital major adverse cardiac events (IH-MACCE). Multivariate logistic models were developed to adjust for differences in baseline and procedural characteristics. RESULTS: The primary operator in 838 (36%) of the PCIs was a supervised FIT. Baseline and procedural characteristics had lower complexity in CHIP-PCI cases carried out by supervised FIT vs consultant. In a multivariate-adjusted model, supervised FIT procedures were associated with lower odds of concurrent valve disease (OR 0.45, 95% CI: 0.29 to 0.69), dual access (OR 0.58, 95% CI: 0.41 to 0.83), cutting/scoring balloons (OR 0.59, 95% CI: 0.44 to 0.79) and rotational atherectomy (OR 0.60, 95% CI: 0.42 to 0.87). After adjusting for all variables, however, there was no difference in the primary outcome (OR 0.72, 95% 0.34 to 1.51) or any secondary outcomes. Sensitivity analyses restricted to patients with higher CHIP Scores (4+ and 5+) showed comparable IH-MACCE. CONCLUSIONS: Training FIT as primary operators in CHIP-PCI appears to be feasible and safe and can be delivered within the standard training programme. The comparable outcomes are likely driven by the two-operator 'buddy' effect that a FIT supervised by a consultant benefits from.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Complex high-risk indicated PCI (CHIP-PCI): is it safe to let fellows-in-training perform it as primary operators?
- Date Crossref
- 01/01/2025
- Éditeur
- BMJ
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.