Abstract Background Global longitudinal strain (GLS) by Speckle-tracking Echocardiography (STE) has emerged as the most sensitive marker of myocardial function with a prognostic value in many cardiac diseases. GLS could also be calculated by cardiac magnetic resonance (CMR) which is the gold standard method for LV morph functional evaluation, applying the feature-tracking (FT) technique. However, there are still difficulties related to the lack of interchangeability between STE and FT techniques and the inter-vendor variability of myocardial deformation parameters. Aim To assess the variability of transmural GLS measurements using different analysis software packages from three different specific vendors (Echo 1-2-3) and to compare the variability of endocardial GLS measurements using an independent vendor software between cine-loops obtained by three different echo machines and CMR. Methods We enrolled 50 healthy volunteers (age 29 ± 3 years, males 60%, BSA 1.7±0.2 m2) without cardiovascular risk factors. All the subjects were in sinus rhythm (HR 69 ± 12 bpm) and had a good acoustic window. Each volunteer underwent an echocardiographic study on three different echo machines on the same day (Echo 1, Echo 2, Echo3). Over the course of a week, 11 patients also underwent a CRM without contrast administration. The images were acquired on each echo machine by an expert operator. All transmural GLS measurements were performed by a single observer using the dedicated post-processing software package of the respective vendor that were based on a semi-automatic method with possible manual adjustments by the operator. The same operator analyzed the cine-loops obtained from the three echo machines and CMR with an independent software which performed the analysis of STE/FT parameters with a semi-automatic method. The following parameters were obtained: left ventricular (LV) Circumferential Global Strain (GCS), GLS, EF, end-diastolic volume (EDV) and end-systolic volume (ESV). Results Comparing the parameters obtained by the three specific software vendors of the echo machines, there were no statistically significant differences in transmural GLS values (p=0.313); (Picture 1). Comparing the parameters obtained by an independent software vendor, there were no statistically significant differences between the endocardial GLS, GCS and EF computed by the software (respectively p=0.290, p=0.655 and p=0.51; (Table 1). Conclusions In clinical practice, transmural GLS do not differ using specific vendor software of different echo machines on a cohort of healthy volunteers. At the same time, endocardial GLS, GCS and EF values calculated by an independent multivendor software using echo cine-loops of three different echo machines do not differ between them and from CMR-FT obtained GLS and GCS values. Picture 1 Table 1

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Exploring the inter-vendor variability of GLS: a myocardial deformation analysis on a cohort of healthy volunteers.
Date Crossref
01/01/2025
Éditeur
Oxford University Press (OUP)
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Cardiovascular Function and Risk Factors

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.