Aller au contenu principal
Accès ouvert déclaré 2025 article

Differences in superficial dose distribution in patients receiving intensity modulated radiotherapy (IMRT) after radical mastectomy

0Citations signalées, ce qui n’est pas une note de qualité
3Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : cn. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Background: The accuracy of the dose on the chest wall in postoperative radiotherapy for breast cancer is critical for clinicians and patients. The objective of this study was to evaluate the superficial dose in patients undergoing radiotherapy after radical mastectomy using deep inspiration breath-hold (DIBH) and free breathing (FB) and to investigate the effects of respiratory amplitude in an anthropomorphic chest phantom. Methods: Thirty patients with left-breast radical mastectomy were prospectively enrolled before radiotherapy. During computed tomography (CT) simulation, half of the patients were treated with DIBH and half with FB. All patients were subjected to intensity modulated radiotherapy (IMRT) with a prescribed dose of 2 Gy. Eight quantum effect devices (QED) detectors were placed on the breast surface to measure the superficial dose. The measured average values from the detectors were compared with the dose calculated using the treatment planning system (TPS). The respiratory motion was simulated using a custom-made moving platform to drive the movement of an anthropomorphic chest phantom in the anterior-posterior direction at four different amplitudes-5, 10, 15, and 20 mm. Using the same detectors, the superficial dose was measured on the phantom during irradiation on the virtual left-side breast target with the same dose. Results: measurements were -2.63% (P=0.01) for FB and -0.107% (P=0.96) for DIBH, with an overall range of 5%. For the phantom, the relative dose differences were 5%, 6%, 8%, and 18% for movement amplitudes of 5, 10, 15, and 20 mm. Conclusions: During IMRT, slight respiratory movement does not cause variations in the superficial dose on the bolus-covered chest wall target. However, respiratory movement at high amplitudes may result in target dose variations of up to 10%.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Differences in superficial dose distribution in patients receiving intensity modulated radiotherapy (IMRT) after radical mastectomy
Date Crossref
01/02/2025
Éditeur
AME Publishing Company
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Advanced Radiotherapy TechniquesBreast Cancer Treatment StudiesRadiation Therapy and Dosimetry

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.