Aller au contenu principal
Accès ouvert déclaré 2025 article

Evaluation of the recombinant protein Sh-TSP-2 for the serological diagnosis of imported urogenital schistosomiasis and comparison with commercially available tests

1Citations signalées — pas une note de qualité
6Institutions déclarées
2Pays d’affiliation déclarés

Résumé fourni par la source

Abstract Different agencies have emphasized the need to evaluate current serological methods for screening patients with suspected urogenital schistosomiasis. However, there is still a lack of evidence regarding the most appropriate methods for this purpose. Here we assessed the diagnostic efficacy of a newly developed serological technique that utilizes the recombinant protein Sh-TSP-2, applied to the urine and serum of migrants suspected of having urogenital schistosomiasis. The sensitivity, specificity, positive and negative predictive values of an in-house enzyme-linked immunosorbent assay (ELISA) using the recombinant protein Sh-TSP-2 were analysed and compared with other commercial serological methods. Due to the limitations of microscopy as a perfect reference method, a latent class analysis (LCA) and composite reference standard (CRS) approach was used to determine the sensitivity and specificity of each test. According to the LCA model, the commercial tests NovaLisa® and immunochromatography test (ICT) immunoglobulin G–immunoglobulin M (IgG–IgM) presented the highest sensitivity (100%), whereas the Sh-TSP-2 serum ELISA test had 79.2%. The Sh-TSP-2 urine and serum ELISA tests had the highest specificities among the serological methods (87.5 and 75%, respectively). CRS modelling showed that the ICT IgG–IgM, NovaLisa® and Sh-TSP-2 serum tests led in sensitivity at 97.1, 88.6 and 71.4%, respectively, with all tests except that the ICT IgG–IgM test having a specificity >90%. Sh-TSP-2 has been validated as a screening tool for patients suspected of having urogenital schistosomiasis. Although commercial serological tests have shown higher sensitivities, Sh-TSP-2 could be valuable for confirming results from tests with lower specificity. Nevertheless, further studies with larger patient cohorts are necessary to fully verify its potential.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé, mais le titre doit être comparé manuellement.

Titre Crossref
Evaluation of the recombinant protein <i>Sh</i>-TSP-2 for the serological diagnosis of imported urogenital schistosomiasis and comparison with commercially available tests
Date Crossref
01/01/2025
Éditeur
Cambridge University Press (CUP)
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Parasites and Host InteractionsParasite Biology and Host InteractionsHelminth infection and control

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref et Europe PMC, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune réponse conservée. Sources et limites.