3D‐printed patient‐specific instrumentation and the freehand technique in high‐tibial osteotomy: A prospective cohort‐comparative study in an outpatient setting
Rattachement africain : es, it. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
Purpose: Tibial valgus osteotomy has shown to be a successful and cost-effective procedure. The advent of image processing and three-dimensional (3D) printing is an interesting tool for achieving more accurate and reproducible results. The aim of our study was to compare the accuracy of the conventional technique and the use of customized guides in the correction of tibial deformities in tibial varus patients, the surgical and clinical benefits, and the impact of treatment in the outpatient setting. Methods: A prospective cohort of 30 patients who underwent tibial valgus osteotomy were selected and randomized into two groups (3D-printed guidewires and conventional techniques). All patients underwent a complete radiological study to plan the surgical procedure. During the surgical procedure, the surgical time and X-ray exposure were analysed. The following results were evaluated: surgical time and X-ray exposure, the correlation between the planned correction and the correction obtained at 3 post-operative months, pre- and post-operative knee injury and osteoarthritis outcome score (KOOS) value at 3 and 12 months, and differences between the two groups in terms of the correction obtained. Results: > 0.05). The KOOS at 3 months were 87.86 (±5.64) for the control group and 88.46 (±3.53) for the 3D-guide group, while at 12 months they were 91.5 (±5.72) for the control group and 88.57 (±8.81) for the 3D-guide group. Conclusion: Customized 3D-printed guides do not permit better correction or functional results than the conventional technique; rather, they reduce surgical time and intraoperative radiation exposure. Level of Evidence: II.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- 3D‐printed patient‐specific instrumentation and the freehand technique in high‐tibial osteotomy: A prospective cohort‐comparative study in an outpatient setting
- Date Crossref
- 01/01/2025
- Éditeur
- Wiley
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.