Basic Performance of highly sensitive Chemiluminescent Enzyme Immunoassay for β‐Amyloid 1‐40 and β‐Amyloid 1‐42
Rattachement africain : jp. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
Abstract Background Alzheimer's disease (AD) is the most common cause of a decline in cognitive ability. The pathogenesis of AD involves the deposition of β‐amyloid (Aβ) plaques and the formation of neurotoxic oligomers of Aβ protein. This leads to neurofibrillary tangles composed of phosphorylated Tau proteins, neuroinflammation, loss of nerve cells and synapses, and ultimately dementia. Recent research suggests that the Aβ1‐42/Aβ1‐40 ratio in plasma can predict amyloid deposition in the brain. However, the small difference between amyloid‐positive and ‐negative subjects results in a very low total allowable error. Therefore, the assay system with high reproducibility is required. Here, we improved Aβ1‐40 and Aβ1‐42 assays in Lumipulse and report the basic performance. Method The Lumipulse system is a fully automated chemiluminescent enzyme immunoassay platform that processes samples in approximately 30 minutes. This assay uses two monoclonal antibodies to capture and detect Aβ1‐40 or Aβ1‐42. Baseline performance was analyzed in a limited set of characterized patient samples. The analytical study included a series of plasma samples (K2EDTA) at various concentration levels, and each analyte was tested in multiple replicates, sized to suit the various parameters tested. Result As shown previously on other LUMIPULSE assays, variability (within‐ and between‐run) was found to be low. An acceptable Limit of Quantification or functional sensitivity was obtained based on the evaluation of low Aβ1‐40 and Aβ1‐42 concentrated serum samples. No cross reactivity toward other Aβ fragments was observed. In the frozen‐thawed samples, no effect was observed for several times. Conclusion These studies showed promising performance with less variability, suggesting that these Aβ assays could be useful in screening appropriate patients for AD therapy.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Basic Performance of highly sensitive Chemiluminescent Enzyme Immunoassay for β‐Amyloid 1‐40 and β‐Amyloid 1‐42
- Date Crossref
- 01/12/2024
- Éditeur
- Wiley
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.